Nt6X30 In An Rsc-S (Pcm-30) Model B Lcme; Unit_No - Nortel DMS-100 Series Replacement Procedures

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

in an RSC-S (PCM-30) Model B LCME
where

unit_no

is the PM unit number (0 or 1) assigned to the faulty RG
If the SWRG command
passed
failed
9
Manually-busy (ManB) the PM unit associated with the faulty RG by typing
>BSY UNIT unit_no
and pressing the Enter key.
where
unit_no
is the PM unit number (0 or 1) associated with the faulty RG
Note: If clearing a critical alarm choose either unit to work on.
Example of a MAP response:
LCME RSC-S 14 0 Unit 0 Bsy Passed
Note: Repeat this command for the other PM in the frame.
10
The next action depends on how many LCMEs are provisioned in the
equipment frame.
If there
is one LCME provisioned in the frame
two LCMEs provisioned in the frame, and you have
not switched RG activity for both LCMEs
two LCMEs provisioned in the frame, and you have
switched RG activity for both LCMEs
11
Repeat step 3 through step 10 for the other LCME provisioned in the
equipment frame.
12
Post both PMs in the frame and ensure all units are now on the good RG by
typing
>POST LCME site frame_no lcme_no site frame_no lcme_no
and pressing the Enter key.
where
site
is the PM location (alphanumeric) of the first LCME
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
Do
step 9
step 38
1-1007
NT6X30
(continued)
Do
step 14
step 11
step 12