07/11/02 09:37:13 61TA0000_190_0133
Symptom Troubleshooting
VSA activation indicator does not go off, and
no DTCs are stored
1. Turn the ignition switch to ON (II).
2. Check the VSA activation indicator for several
seconds when the ignition switch is turned to
ON (II).
Does the indicator come on then go of f ?
YES
−
The system is OK at this time.
NO
−
Go to step 3.
3. Turn the ignition switch to LOCK (0).
4. Disconnect the VSA OFF switch 5P connector.
5. Check the VSA OFF switch (see page 19-139).
Is the V SA OF F switch OK ?
YES
−
Go to step 6.
NO
−
Replace the VSA OFF switch (see page
19-139).
6. Disconnect the gauge control module 32P
connector.
7. Check for continuity between VSA OFF switch 5P
connector terminal No. 2 and body ground.
VSA OFF SWITCH 5P CONNECTOR
BRN
Wire side of female terminals
Is there continuity?
YES
−
Repair short to body ground between the
gauge control module and the VSA OFF switch.
NO
−
Substitute a known-good gauge control
module, then go to step 1 and recheck. If it is OK,
replace the original gauge control module
(see page 22-332).
TA08A00D52100000000FAAT04
*06
19-133