Omron G5 Series User Manual page 371

Ac servomotors/servo drives. pulse-train input type
Hide thumbs Also See for G5 Series:
Table of Contents

Advertisement

Pn431
Positioning Completion Range 1
Setting
0 to 262,144
range
• Use this parameter in combination with Positioning Completion Condition Selection (Pn432) to set
the output timing of the positioning completion output. The positioning completion output (INP) will be
output if, after command pulse input, the Servomotor (workpiece) completes its movement and the
number of pulses in the error counter falls within the range defined as "±(set value)."
• Although the setting unit is command units, you can change it to encoder units in Position Setting Unit
Selection (Pn520). However, note that the unit for error counter overflow level is changed as well.
• If the parameter value is set too small, the time until the INP signal is output may increase or
chattering may appear in the output signal. Positioning Completion Range settings do not affect on
the final positioning accuracy.
Accumulated
pulse
Pn432
Positioning Completion Condition Selection
Setting
0 to 3
range
Explanation of Set Values
Set value
0
The positioning completion output turns ON when the position error is equal to or less than
Positioning Completion Range 1 (Pn431).
1
The positioning completion output turns ON when there is no position command and the position
error is equal to or less than Positioning Completion Range 1 (Pn431).
2
The positioning completion output turns ON when there is no position command, the zero speed
detection signal is ON, and the position error is equal to or less than Positioning Completion Range
1 (Pn431).
3
The positioning completion output turns ON when there is no position command and the position
error is equal to or less than Positioning Completion Range 1 (Pn431). Then, the ON status is held
until the time set in Positioning Completion Hold Time (Pn433) expires and, after that, the ON/OFF
status is determined according to the position error status.
• Use this parameter in combination with Positioning Completion Range 1 (Pn431) to set the behavior
of the positioning completion output (INP: CN1 pin 39).
Pn433
Positioning Completion Hold Time
Setting
0 to 30,000
range
• The positioning completion hold time is infinite when Pn433 is set to 0 and the ON status will be held
until the next position command is input.
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Unit
Command units
ON
INP
Unit
Unit
1 ms
Default
setting
Pn431
Pn431
Default
setting
Description
Default
setting
7 Parameter Details
Position
10
Cycle the
power supply
Position
0
Cycle the
power supply
Position
0
Cycle the
power supply
7 - 37
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G5 r88d-ke seriesG5 r88m-kp series