Pn419
Analog Monitor 2 Scale Setting
Setting
0 to 214,748,364
range
• Set the output gain of the analog monitor 2.
Pn421
Analog Monitor Output Setting
Setting
0 to 2
range
• Select the analog monitor output voltage direction.
Set value
0
1
2
• An example when the monitor type is Motor speed and the conversion gain is 500 (1 V = 500 r/min)
Pn422
Reserved
Setting
0
range
• Do not set.
Pn423
Reserved
Setting
0
range
• Do not set.
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Unit
Pn418 monitor unit/V
Unit
Output range
–10 to 10 V
0 to 10 V
0 to 10 V
Unit
Unit
Default
setting
Default
setting
Data output
Output voltage [V]
10 V
0 V
–5,000
5,000 [r/min]
–10 V
Output voltage [V]
10 V
–5,000
0 V
5,000 [r/min]
–10 V
Output voltage [V]
10 V
5 V
0 V
0
–2,500
–10 V
Default
setting
Default
setting
7 Parameter Details
All
0
Cycle the
power supply
All
0
Cycle the
power supply
Motor
speed
Motor
speed
Motor
speed
5,000 [r/min]
0
Cycle the
power supply
0
Cycle the
power supply
7 - 35