Radio Noise Filter and Emission Noise Prevention Clamp Core
Use one of the following filters to prevent switching noise of PWM of the Servo Drive and to prevent
noise emitted from the internal clock circuit.
Model
*1
3G3AX-ZCL1
*2
3G3AX-ZCL2
*3
ESD-R-47B
*4
ZCAT3035-1330
RJ8035
RJ8095
T400-61D
*1 Generally used for 1.5 kW or higher.
*2 Generally used for 1.5 kW or lower. The maximum number of windings is 3 turns.
*3 Generally used for 50/100 W. The maximum number of windings is 2 turns.
*4 Also used on the Drive output power lines to comply with the EMC Directives. Only a clamp is used. This clamp
can also be used to reduce noise current on a FG line.
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Manufacturer
OMRON
For Drive output and power cable
OMRON
For Drive output and power cable
NEC TOKIN
For Drive output and power cable
TDK
For Encoder cable and I/O cable
Konno Industry
For power supply line
Konno Industry
For power supply line
MICROMETALS
For Drive output and power cable