Omron G5 Series User Manual page 108

Ac servomotors/servo drives. pulse-train input type
Hide thumbs Also See for G5 Series:
Table of Contents

Advertisement

3 Specifications
R88D-KP30H/R88D-KP50H
Main Circuit Terminal Block Specifications
Symbol
L1
Main circuit power supply
input
L2
L3
L1C
Control circuit power
supply input
L2C
B1
External Regeneration
Resistor connection
B3
terminals
B2
NC
Do not connect.
U
Motor connection
terminals
V
W
Precautions for Correct Use
Precautions for Correct Use
• Tighten the terminal block screws to a torque of 0.75 N·m (M4) or 1.5 N·m (M5).
• If the torque for terminal block screws exceeds 1.2 N·m (M4) or 2.0 N·m (M5), the terminal
block may be damaged.
• Tighten the fixing screw of the terminal block cover to a torque of 0.2 N·m (M3).
• Tighten the ground screws to a torque of 0.7 to 0.8 N·m (M4) or 1.4 to 1.6 N·m (M5).
• Do not connect any External Regeneration Resistors between B1 and NC.
3 - 8
Name
R88D-KP H (3 to 5 kW):
3-phase 200 to 230 VAC (170 to 253 VAC) 50/60 Hz
R88D-KP H: Single-phase 200 to 230 VAC (170 to 253 VAC) 50/60 Hz
Normally B2 and B3 are shorted. Do not short B1 and B2. Doing so may
result in a malfunction.
If there is high regenerative energy, remove the short-circuit bar between
B2 and B3 and connect an External Regeneration Resistor between B1 and
B2.
Phase U
Phase V
Phase W
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Function
These are the output terminals to the Servomotor.
Be sure to wire them correctly.