Omron G5 Series User Manual page 479

Ac servomotors/servo drives. pulse-train input type
Hide thumbs Also See for G5 Series:
Table of Contents

Advertisement

Pn
Name
No.
016 Regeneration
Resistor
Selection
017 External
Regeneration
Resistor
Setting
*1 The default setting is 11 for a Servo Drive with 200 V and 1 kW or more.
*2 The default setting is 0 for a Servo Drive with 200 V and 750 W or more.
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Setting
Description
Select the Regeneration Resistor to be used.
0
Uses the Built-in Resistor.
The Regeneration Overload
Protection (Alarm No.18) is enabled
according to the Built-in Resistor
(with approx. 1% duty).
1
Uses the External Resistor.
The regeneration processing circuit
operates and Regeneration Overload
Protection (Alarm No.18) is enabled
when the operating rate of the
Regeneration Resistor is over 10%.
2
Uses the External Resistor.
Regeneration Overload Protection
(Alarm No.18) is disabled.
3
No Regeneration Resistors.
All regenerative energy is processed
by the built-in capacitor.
Select the load ratio calculation type for the
External Regeneration Resistor.
0
Regeneration load ratio is 100%
when the operating rate of the
External Regeneration Resistor is
10%.
1
Reserved
2
Reserved
3
Reserved
4
Reserved
Appendices
Default
Setting
Unit
setting
range
*2
0 to 3
3
0
0
Cycle the
power
supply
Required
A
Required
A - 13