7 Parameter Details
• For details about the display, refer to 8-4 Mode Setting on page 8-6.
Pn531
Reserved
Setting
1
range
• Do not set.
Pn532
Command Pulse Input Maximum Setting
Setting
250 to 4,000
range
• Set the maximum command pulse input value. A Command Pulse Frequency Error (Alarm No. 27.0)
occurs if the command pulse input frequency exceeds this value x 1.2.
• The Servo Drive detects the Command Pulse Frequency Error for pulses it has accepted. Therefore,
if may not detect the error if the number of input pulses is much larger than the value set in this
parameter. In addition, setting the value to 1,000 or less enables the use of the digital filter for the
command pulse input as shown in the table below.
Pn532 set value
250 to 499
500 to 999
1,000 to 4,000
Pn533
Pulse Regeneration Output Limit Setting
Setting
0 to 1
range
Explanation of Set Values
Set value
0
Error detection disabled
1
Error detection enabled
• Set whether to enable or disable the detection of the Pulse Regeneration Error (Alarm No. 28.0).
Pn535
Front Key Protection Setting
Setting
0 to 1
range
Explanation of Set Values
Set value
0
Front panel operation not restricted
1
Front panel operation restricted
• Set whether or not to restrict operations on the front panel.
• The restricted operation varies depending on the mode as shown in the table below.
Mode
Monitor Mode
Parameter Setting Mode
EEPROM Write Mode
Ancillary Function Mode
7 - 54
Unit
Unit
Kpps
200 ns × 2 readings
100 ns × 2 readings
None (through)
Unit
Unit
All monitor data can be viewed.
Parameters cannot be changed. However, set parameter values can be viewed.
Unavailable (Not displayed)
Operations other than disabling the front key protection setting are unavailable
(not displayed).
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Default
1
setting
Default
4,000
setting
Digital filter
Default
0
setting
Description
Default
0
setting
Description
Operations restricted
Cycle the
power supply
Position
Cycle the
Required
power supply
All
Cycle the
Required
power supply
All
Cycle the
Required
power supply

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G5 r88d-ke seriesG5 r88m-kp series

Table of Contents