5 Basic Control Mode
Command Pulse Rotation Direction Switching Selection and Command Pulse Mode Selection settings
are as follows.
Pn006
Pn007
0
0 or 2
1
3
1
0 or 2
1
3
Symbol
+CWLD, –CWLD,
+CCWLD, –CCWLD
+CW, –CW,
+CCW, –CCW
5 - 4
Command pulse
Signal
pattern
90° phase
PULS
difference
2-phase pulse
(Phase A and
SIGN
Phase B)
Forward direction
PULS
pulse train
+
Reverse direction
SIGN
pulse train
Pulse train
PULS
+
Sign
SIGN
90° phase
PULS
difference
2-phase pulse
(Phase A and
SIGN
Phase B)
Forward direction
PULS
pulse train
+
Reverse direction
SIGN
pulse train
Pulse train
PULS
+
Sign
SIGN
Maximum
allowable input
frequency
4 Mpps
Line driver
500 kpps
Open collector
200 kpps
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Forward direction
command
t1
Phase
t1
A
t1
t1
Phase
B
Phase B is 90° ahead of phase A.
Phase B is 90° behind phase A.
t3
t2
t2
t5
t4
H
t6
t6
t1
t1
Phase
A
t1
t1
Phase
B
Phase B is 90° ahead of phase A.
t2
t2
t3
t5
t4
t6
t6
L
Minimum required duration [µs]
t1
t2
t3
0.25
0.125
0.125
2
1
1
5
2.5
2.5
Reverse direction
command
t1
t1
t1
t1
t2
t2
t5
t4
t6
t6
L
t1
t1
t1
t1
Phase B is 90° behind phase A.
t2
t2
t5
t4
t6
t6
H
t4
t5
t6
0.125
0.125
0.125
1
1
1
2.5
2.5
2.5

Hide quick links: