Pn633
Reserved
Setting
1,000
range
• Do not set.
Pn634
Reserved
Setting
0
range
• Do not set.
Pn635
Reserved
Setting
10
range
• Do not set.
Pn637
Vibration Detection Threshold
Setting
0 to 1,000
range
• Set the vibration detection threshold.
• If torque vibration that exceeds this setting is detected, a vibration detection warning occurs.
• The unit is 0.1% of the rated torque.
Pn638
Warning Mask Setting
Setting
–32,768 to 32,767
range
• Set a mask for warning detection.
• If you set the corresponding bit to 1, the corresponding warning detection is disabled.
• For the setting method, refer to 10-2 Warning List on page 10-5.
Precautions for Correct Use
Precautions for Correct Use
Pn700 to Pn799 and Pn800 to Pn899 are not used. Do not change the settings.
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Unit
Unit
Unit
Unit
0.1%
Unit
7 Parameter Details
Default
1,000
Cycle the
setting
power supply
Default
0
Cycle the
setting
power supply
Default
10
Cycle the
setting
power supply
Default
0
Cycle the
setting
power supply
Default
4
Cycle the
setting
power supply
All
All
Required
7
7 - 61