7 Parameter Details
Pn617
Front Panel Parameter Write Selection
Setting
0 to 1
range
Explanation of Set Values
Set value
0
Writing to the EEPROM is not performed simultaneously with parameter changes.
1
Writing to the EEPROM is performed simultaneously with parameter changes.
• Select whether to write to the EEPROM when a parameter is changed from the front panel.
Pn618
Power Supply ON Initialization Time
Setting
0 to 100
range
• Set the initialization time after turning ON the power supply to the standard 1.5 seconds plus the
specified value.
Pn619
Encoder Phase-Z Setting
Setting
0 to 32,767
range
• Make fine adjustment to the encoder phase-Z width if the number of pulses per motor rotation after
pulse output dividing is not an integer.
Pn620
Reserved
Setting
0
range
• Do not set.
Pn621
Reserved
Setting
0
range
• Do not set.
Pn622
Reserved
Setting
0
range
• Do not set.
Pn623
Disturbance Torque Compensation Gain
Setting
–100 to 100
range
• Set the compensation gain for the disturbance torque.
Pn624
Disturbance Observer Filter Setting
Setting
10 to 2,500
range
• Set the filter time constant for disturbance torque compensation.
7 - 58
Unit
–
Unit
0.1 s
Unit
Pulses
Unit
–
Unit
–
Unit
–
Unit
%
Unit
0.01 ms
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Default
0
setting
Description
Default
0
setting
Default
0
setting
Default
0
setting
Default
0
setting
Default
0
setting
Default
0
setting
Default
53
setting
All
Cycle the
Required
power supply
All
Cycle the
Required
power supply
All
Cycle the
Required
power supply
Cycle the
–
power supply
Cycle the
–
power supply
Cycle the
–
power supply
Position
Cycle the
–
power supply
Position
Cycle the
–
power supply