Omron G5 Series User Manual page 277

Ac servomotors/servo drives. pulse-train input type
Hide thumbs Also See for G5 Series:
Table of Contents

Advertisement

Precautions for Correct Use
Precautions for Correct Use
If more than one internally set speed selection signal is switched at the same time (e.g., as when
switching from Speed 2 to Speed 3), an internally set speed signal in the process of switching
may be temporarily selected. (For example, Speed 1 or Speed 4 may be temporarily selected.)
The internally set speed command may be temporarily performed with a sudden change,
especially if the acceleration or deceleration time is set to 0 or small value, or if the speed
difference between internally set speed commands is large. Use this function with the following
precautions.
• Avoid switching more than one internally set speed selection signal at the same time.
• Set both Soft Start Acceleration Time and Soft Start Deceleration Time so that the speed
changes gradually and avoid a sudden change.
Internal Speed Command (Pn304 to Pn311)
The internal speed command controls the motor speed according to the internal speed command value
set in the parameter.
The internally set speed is enabled when Command Speed Selection (Pn300) is set to 1 or 3.
Up to eight internally set speeds can be set.
Parameter
No.
Pn304
No. 1 Internally Set Speed
Pn305
No. 2 Internally Set Speed
Pn306
No. 3 Internally Set Speed
Pn307
No. 4 Internally Set Speed
Pn308
No. 5 Internally Set Speed
Pn309
No. 6 Internally Set Speed
Pn310
No. 7 Internally Set Speed
Pn311
No. 8 Internally Set Speed
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Name
Set the first internally set speed.
Set the second internally set speed.
Set the third internally set speed.
Set the fourth internally set speed.
Set the fifth internally set speed.
Set the sixth internally set speed.
Set the seventh internally set speed.
Set the eighth internally set speed.
5 Basic Control Mode
Description
Setting range
Unit
–20,000 to
r/min
20,000
–20,000 to
r/min
20,000
–20,000 to
r/min
20,000
–20,000 to
r/min
20,000
–20,000 to
r/min
20,000
–20,000 to
r/min
20,000
–20,000 to
r/min
20,000
–20,000 to
r/min
20,000