4 System Design
Wire Sizes and Allowable Current (Reference)
The following table shows the allowable current when there are 3 power supply wires. Use a current
below these specified values.
600-V Heat-resistant Vinyl Wire (HIV)
Nominal cross-
sectional area
AWG size
20
18
16
14
12
10
8
6
4
4 - 18
Configuration
2
[wires/mm
]
2
[mm
]
0.5
19/0.18
0.75
30/0.18
0.9
37/0.18
1.25
50/0.18
2.0
7/0.6
3.5
7/0.8
5.5
7/1.0
8.0
7/1.2
14.0
7/1.6
22.0
7/2.0
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Allowable current [A] for
Conductive
ambient temperature
resistance
[Ω/km]
30°C
39.5
6.6
26.0
8.8
24.4
9.0
15.6
12.0
9.53
23
5.41
33
3.47
43
2.41
55
1.35
79
0.85
99
40°C
50°C
5.6
4.5
7.0
5.5
7.7
6.0
11.0
8.5
20
16
29
24
38
31
49
40
70
57
88
70

Hide quick links: