Advertisement

5 Basic Control Mode
Internally Set Speed Selection
The following tables show the internally set speeds that are set with VSEL1, VSEL2 and VSEL3
(internally set speed selection 1, 2 and 3).
Pn300 =1
No.
0
1
2
3
Pn300 = 3
No.
0
1
2
3
4
5
6
7
Operation Example
• Internally set speed control with 4 speed changes when Pn300 is set to 1
Operation Command (RUN)
Zero Speed Specified (VZERO)
Internally Set Speed Selection 1 (VSEL1)
Internally Set Speed Selection 2 (VSEL2)
*1 The acceleration time, deceleration time, and S-curve acceleration/deceleration time can be set in parameters
Pn312, Pn313, and Pn314, respectively.
5 - 8
VSEL1
VSEL2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
VSEL1
VSEL2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Stop
Speed
(*1)
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
VSEL3
Disabled
Disabled
Disabled
Disabled
VSEL3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Servo ON
Drive
Closed
Closed
Open
Closed
Open
Open
Speed 2
Speed 4
Speed 1
Set speed
Pn304
Pn305
Pn306
Pn307
Set speed
Pn304
Pn305
Pn306
Pn307
Pn308
Pn309
Pn310
Pn311
Open
Closed
Speed 3
Time t