Omron G5 Series User Manual page 375

Ac servomotors/servo drives. pulse-train input type
Hide thumbs Also See for G5 Series:
Table of Contents

Advertisement

Pn439
Brake Release Speed Setting
Setting
30 to 3,000
range
Pn440
Warning Output Selection 1
Setting
0 to 10
range
Explanation of Set Values
Set value
0
OR output for all types of warnings
1
Overload warning
2
Excessive regeneration warning
3
Battery warning
4
Fan warning
5
Encoder communications warning
6
Encoder overheating warning
7
Vibration detection warning
8
Service life detection warning
9
Reserved (Do not set.)
10
Reserved (Do not set.)
• For the setting method, refer also to 10-2 Warning List on page 10-5.
Pn441
Warning Output Selection 2
Setting
0 to 10
range
• For this parameter, set the same value as for Warning Output Selection 1 (Pn440).
Pn442
Positioning Completion Range 2
Setting
0 to 262,144
range
• Set the positioning completion range.
• For this parameter, set the same value as for Positioning Completion Range 1 (Pn431).
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Unit
Pn438 set value
Released (ON)
*1
t1
Motor rotation speed
Pn439 set value
Pn438 set
value
Released (ON)
*1
t1
Motor rotation speed
Pn439 set value
Unit
Unit
Unit
Command units
r/min
Default
setting
Applied (OFF)
When the set time in Pn438
comes earlier.
Applied (OFF)
When the time to reach the set
value or less in Pn439 comes earlier.
Default
setting
Description
Default
setting
Default
setting
7 Parameter Details
All
30
Cycle the
power supply
All
0
Cycle the
power supply
All
0
Cycle the
power supply
Position
10
Cycle the
power supply
7 - 41
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G5 r88d-ke seriesG5 r88m-kp series