Omron G5 Series User Manual page 490

Ac servomotors/servo drives. pulse-train input type
Hide thumbs Also See for G5 Series:
Table of Contents

Advertisement

Appendices
Expansion Setting Parameters
Pn
Name
No.
500 Electronic Gear
Ratio
Numerator 2
501 Electronic Gear
Ratio
Numerator 3
502 Electronic Gear
Ratio
Numerator 4
503 Encoder
Dividing
Denominator
504 Drive
Prohibition
Input Selection
505 Stop Selection
for Drive
Prohibition
Input
A - 24
Setting
Description
Set the electronic gear ratio.
If Pn500, Pn501, or Pn502 = 0, the encoder
resolution is set in the numerator.
Electronic Gear Ratio Numerator 2 (Pn500)
or
Electronic Gear Ratio Numerator 3 (Pn501)
or
Electronic Gear Ratio Numerator 4 (Pn502)
Electronic Gear Ratio Denominator (Pn010)
Set the denominator if the number of pulses per
motor rotation is not an integer in pulse
regeneration.
Set the operation to be performed upon forward/
reverse drive prohibition input.
0
Forward or reverse drive prohibition
input enabled
1
Forward or reverse drive prohibition
input disabled
2
Forward or reverse drive prohibition
input enabled
Make the setting upon drive prohibition input.
0
The torque in the drive prohibit
direction is disabled, and the
dynamic brake is activated.
1
The torque in the drive prohibit
direction is disabled, and free-run
deceleration is performed.
2
The torque in the drive prohibit
direction is disabled, and an
immediate stop is performed.
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User's Manual
Default
Setting
Unit
setting
range
0
30
0 to 2
0
30
0 to 2
0
30
0 to 2
0
0 to
262,144
1
0 to 2
0
0 to 2
Cycle the
power
supply
Required
Required
Required

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G5 r88d-ke seriesG5 r88m-kp series

Table of Contents