Agilent Technologies 93000 SOC Series Training Manual page 623

Mixed-signal training
Hide thumbs Also See for 93000 SOC Series:
Table of Contents

Advertisement

internal referencing
TLC5510
The three internal resistors shown with V
out on V
, REFTS, REFT, REFB, REFBS, and AGND.
DDA
To use the internally generated reference voltage, terminal connections should be made as shown in Figure 3.
This connection provides the standard video 2-V reference for the nominal digital output.
Figure 3. External Connections for a 2-V Analog Input Span Using the Internal-Reference Resistor Divider
TLC5510A
For an analog input span of 4 V, 4 V is supplied to REFT, and REFB is grounded and terminal connections should
be made as shown in Figure 4. This connection provides the 4-V reference for the nominal zero to full-scale
digital output with a 4 V
(analog supply)
Figure 4. External Connections for 4-V Analog Input Span
8-BIT HIGH-SPEED ANALOG-TO-DIGITAL CONVERTERS
PRINCIPLES OF OPERATION
can generate a 2-V reference voltage. These resistors are brought
DDA
V DDA
18
(analog supply)
REFTS
16
17
REFT
REFB
23
22
REFBS
AGND
21
analog input at ANALOG IN.
pp
18
V DDA
16
REFTS
17
4 V
REFT
REFB
23
22
REFBS
21
AGND
POST OFFICE BOX 655303
SLAS095L – SEPTEMBER 1994 – REVISED JUNE 2003
TLC5510
R1
320 Ω NOM
R ref
270 Ω NOM
R2
80 Ω NOM
TLC5510A
R1
320 Ω NOM
R ref
270 Ω NOM
R2
80 Ω NOM
DALLAS, TEXAS 75265
TLC5510, TLC5510A
Appendix D
623