Agilent Technologies 93000 SOC Series Training Manual page 335

Mixed-signal training
Hide thumbs Also See for 93000 SOC Series:
Table of Contents

Advertisement

For Selective Capturing:
You should use a designated 'capture' device cycle and also a
designated 'do not capture' device cycle in the vectors to
determine at which vector data is to be captured and at which
vector not. How to set up such device cycles has been described
above.
The figure below shows an example of a vector label for Selective
Capturing at the serial output of an ADC (ADC_D1 pin) with the
cap and nocap device cycles used.
Vector Label for Selective Capturing
In the vector label shown above, only 64 bits of data get captured,
while 3072 bits do not get captured.
Settings for Digital Capture
The Digital Capture settings define
the digital pins to be used for capturing
which capture mode to use (Standard Mode or Double Mode)
The Vector Editor provides the menu D
Capture settings, and to set up vector variables.
Lesson 3 – Setting Up the Digital Capturing
D
to enter Digital
IG
ATA
335