Lesson 2 – Creating a Test Method
Supported APIs
Data File for
Emulator
The following APIs are supported by the Emulator:
• DGT().getWaveform ()
• TIA.getMean(),.getMean(),.getMin(),.getMax(),.getJitter()
• Vector().getVector()
• SpecSearch API;
.getResultSpec(),.getPassVal(),.getFailVal()
• PMU_IFVM(),PMU_VFIM(),DPS_VFIM(),PPMU_MEASURE
• FW_TASK(command,answer)
• GET_FUNCTIONAL_RESULT()
• TEST() (except DC test)
Data to be returned by the Emulator is previously prepared in the
file that is called "Hardware (HW) Response File". This file
contains the hardware response data such as analog waveform
data, measurement values and so on, or pass/fail result of a
testsuite. HW Response Files for a testflow can be created by
executing a testflow using the Emulator in "Store" mode. You can
apply one of the following data to the HW Response File:
Online test results
By executing a testflow or testsuite(s) online using the Emulator
in "Store" mode, the Emulator stores the test result (pass/fail) and
hardware response data in different files automatically when the
execution reaches the end of the testsuite or the test method API
for retrieving hardware response data.
Testsuite
Online Mode:
(Test Method Program)
Test Execution
Access
Emulator
(Store mode)
Storing Online Measurement Data using Emulator
User-programmed data
By executing a testflow or testsuite(s) offline using the Emulator
in "Store" mode, the Emulator opens the prompt window
interactively when the execution reaches the end of the testsuite
or the test method API for retrieving hardware response data. In
the window, you can specify the desired data file as virtual test
464
API for retrieving
hardware response
Data
Store hardware
response data
File
Judge pass/fail
of testsuite
Store test result
data (pass/fail)
File