Lesson 3 – Special Synchronization Options
You can define any module in the loop of the "Master-Slave" internal
connection as master or slave. To define the slave module, use the ACMD
"SYNM" firmware command. If you define a module as a slave module,
the upstream module in the internal connection loop is defined as a master
module automatically. You can get the information about the "Master-
Slave" internal connection with the SOCB? firmware command.
The following figure is the block diagram for when the master/slave trigger
function is used:
Digital Pin
Digital Channel
Board
Master
Master
Clock 1
Clock 2
Master/slave Trigger Function
For High Speed AWGs, 500M AWGs, and 1GHz Digitizers, the trigger-to-
signal delay for master and slave modules is always fixed and is the same
as when the master/slave trigger function is not used.
For Dual High Speed Samplers, 3GHz Samplers, or 100MHz Digitizer, the
trigger-to-signal delay for master and slave modules is different according
to the number of slave modules as follows:
For Dual High Speed Samplers:
Trigger-to-Signal Delay = 70 ns + (N x 15 ns)
where, N is the number of the slave modules for one master module.
For 3GHz Samplers:
Trigger-to-Signal Delay = 170 ns + (N x 15 ns)
where, N is the number of the slave modules for one master module.
For 100MHz digitizers:
Trigger-to-Signal Delay = 410 ns + 40 ns
This is fixed when the master/slave function is used for WDG, because
one master module of WDG can have only one slave module.
544
Trigger
Signal
pin
pin
Vernier
Vernier
FF
DAC
Master trigger
Master trigger
Timing
Counter
Counter
Generator
Analog Module (Master)
Analog Module (Slave)
Trigger
Signal
pin
pin
FF
DAC
Timing
Generator

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents