Lesson 2 – Waveform Digitizer Setup with the Analog Setup Tool
With the Analog Setup Tool, you create analog sets that contain all
setup information for the analog modules.
An analog set includes the complete hardware sequencer and
clock domain setup for all cores, but not the routing of the signal
lines. The routing is stored in routing sets.
The commands within a sequencer program specify
– the sequencer operation (such as continue or wait for trigger)
– the sequencer reaction to a trigger signal
– waveform labels (arrays in the waveform memory of an analog
core)
– the number of initial data points to be discarded
The waveform memory is automatically partitioned according to
the defined waveform labels.
Waveform labels can be defined when creating a sequencer
program. They can also be defined and changed in size
independently from a sequencer program.
You can save up to 256 analog sets in one analog setup file on the
workstation.
The available hardware memory space for sequencer programs
and waveform data depends on the chosen analog module core.
For example: The sequencer memory of a High Speed Digitizer
can store up to 64 command lines. The waveform memory of this
module has a capacity of 512 K words.