TIA Arming Setup Section
There are two ways to provide the arming signal. They differ in the
source of the signal.
Source = EXTERNAL
•
In this mode, the TIA is armed when it detects an edge on the
external trigger input.
Slope Mode = RISING
A rising edge arms the TIA.
Slope Mode = FALLING
A falling edge arms the TIA.
Source = AUTO
•
In this mode, the TIA is armed when it detects an edge on one of
the input channels.
Slope Mode = RISING
A rising edge arms the TIA.
Slope Mode = FALLING
A falling edge arms the TIA.
Sequence Mode = START
TIA input channel 1 is used for the arming.
Sequence Mode = STOP
TIA input channel 2 is used for the arming.
Sequence Mode = STARTFIRST
TIA input channel 1 is used for the arming.
Lesson 2 – TIA Setup
489