Agilent Technologies 93000 SOC Series Training Manual page 117

Mixed-signal training
Hide thumbs Also See for 93000 SOC Series:
Table of Contents

Advertisement

N OT E
Simultaneously Available Core Functions in Source Unit
In the core functions of a source unit, the following combination
can be used simultaneously:
V source and any AWG, in any one of the following combinations:
V source on XX+ and Any AWG on X+/X-
V source on XX- and Any AWG on X+/X-
SRCA (one unit)
For single-ended: One of X+/X-
For differential:
X+ / X-
One of XX+/XX-
XX+ / XX-
XX+ is not available if it is used by unit trigger.
If you trigger a unit from the unit trigger pin (the XX+ pin of the unit)
instead of a common trigger pin, the XX+ pin (which should be
connected to a digital channel as the trigger source on the DUT board)
is occupied by the unit trigger function throughout the testflow. Thus,
you cannot use the core function on the XX++ pin throughout the
testflow.
Lesson 1 – Analog Modules
X+&X- pair
Audio AWG or Video AWG
V Source
core-function
117

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents