Lesson 1 – Analog Modules
source&measure module, and sites 5 through 8 can use the
digitizer in the measure module.
Specifications of MCA
The following tables show the specifications and characteristics of
the MCA.
The Multi-site Baseband Analog Source & Measure (E9714A)
consists of four source units and four measure units.
The Multi-site Baseband Analog Measure (E9715A) consists of
eight measure units.
Source unit (SRCA) selectable function:
•
Audio AWG
–
–
Video AWG
PMU
–
V Source
–
Measure unit (MESA) selectable function:
•
Audio Digitizer (containing two digitizer cores)
–
Video Digitizer – normal mode
–
Video Digitizer – direct mode
–
PMU
–
V Source
–
108