You can choose between several measurement units.
The software provides two calculation alternatives:
Nominal calculation
Device-dependent calculation
The nominal calculation refers to an ideal DAC, the device-
dependent calculation takes the measured offset into account.
Discrete Analog
Output Voltage
n
V(2 -1)
V(0)
Definition of Device-Dependent Full Scale Gain Error
The following formulas are used:
Digital Input code
Appendix B