Agilent Technologies 93000 SOC Series Training Manual page 113

Mixed-signal training
Hide thumbs Also See for 93000 SOC Series:
Table of Contents

Advertisement

PMU in Source Unit or Measure Unit
Table 23
Specification
Pin counts
Voltage Force or Measure:
Range
Resolution
Accuracy
Current Measure or Force:
Range
Resolution
Accuracy
MCA-PMU Specifications
Value
4 (one at a time) per source unit or measure unit.
8 source or measure units in module
Source Unit (SRCA):
-2.0 V to +3.5 V
Measure Unit (MESA):
-2.0 V to +3 V
0.1 mV
Force:
±0.1% of setting ±5mV ±(Ia × 60)
Measure:
±0.1% of reading ±5mV ±(Ia × 15)
Ia is the actual current.
±3 mA
0.1 µA
Force:
±0.1% of setting ±5µA ±(Va × 2µA)
(Va is the actual voltage in unit of volt)
Measure:
±0.1% of reading ±5µA
Lesson 1 – Analog Modules