Agilent Technologies 93000 SOC Series Training Manual page 106

Mixed-signal training
Hide thumbs Also See for 93000 SOC Series:
Table of Contents

Advertisement

Lesson 1 – Analog Modules
Maximum Number of Inputs and Outputs in Each Function per Source
Unit or Measure Unit
The following table shows the maximum number of inputs and
outputs in each function per source unit or measure unit. Each of
the maximum numbers shown in the table and the following two
tables are available when only the one core function is used.
Core Function
Audio AWG
Video AWG
PMU (DC)
Audio Digitizer, 2 cores
Video Digitizer - normal mode (15MHz-BW)
Video Digitizer - Direct mode (100MHz-BW)
PMU (DC)
*: This number is available when the unit is configured to be triggered from a common trigger pin.
If two audio digitizer cores in a measure unit is used, both audio
digitizer cores in the measure unit should be configured to the
same site.
Maximum Number of Inputs and Outputs in Each Function in
Source&Measure Module
The following table shows the maximum numbers for the multi-site
baseband analog source & measure, which contains four source
units and four measure units. These numbers are four times those
shown in the previous table.
Core Function
(For Source&Measure Module)
Audio AWG - 1.024Msps 125kHz-Sine 24-bit
Video AWG - 100Msps 25MHz-Sine 14-bit
PMU
(DC)
Audio Digitizer - 200ksps 50kHz-BW 24-bit
Video Digitizer - 65Msps 15MHz-BW 14-bit
Video Digitizer - 65Msps 100MHz-BW 14-bit
*: This number is available when the units are configured to be triggered from the common trigger pins.
Maximum Number of Inputs and Outputs in Each Function in Measure
Module
The following shows the maximum numbers for the multi-site
baseband analog measure, which contains eight measure units.
106
Max number of Inputs/Outputs (or Sites) per Unit
For Single-ended
Serial test
Parallel test
Serial test
2
1
2
4 *
1
4 (2 sites) *
2 (1 site)
2
1
2 *
4 *
1
Max number of Inputs/Outputs (or Sites)
For Single-ended
Serial test
Parallel test
Serial test
8
4
8
32 *
8
16 (8 sites) *
8 (4 sites)
8
4
8 *
For Differential
Parallel test
1
---
2 (1 site) *
1
1 *
---
For Differential
Parallel test
4
---
8 (4 sites) *
4
4 *

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents