Video Digitizer - Normal Mode in Measure Unit
Table 21
Specification
Sampling rate
Resolution
Bandwidth @-3 dB
(characteristic data)
Pin counts
Waveform capture memory
Input range
DC offset range
Common mode range
(AC+DC)
Input impedance
(nominal value)
Filter
Video Digitizer Normal Mode Key Specifications
Value
500 ksps to 65 Msps
14-bit
15 MHz
2 single-ended (one at a time) or 1 differential per measure unit.
For Multi-site Baseband Analog Source & Measure:
4 measure units in module. 4-parallel test
For Multi-site Baseband Analog Measure
8 measure units in module. 8-parallel test
14 M samples per measure unit
(@ no averaging nor over-sampling mode)
±2 V, ±1 V, ±0.5, ±0.25 V
For ±2 V or ±1 V input range:
±3 V (No offset for single-ended 37.5 ohm input impedance)
For ±0.5 V or ±0.25 V input range:
±2.8 V (No offset for single-ended 37.5 ohm input impedance)
±3 V for ±2 V or ±1 V input range
±2.8 V for ±0.5 V or ±0.25 V input range
Within input range for 37.5 ohm single-ended or 75 ohm differential
Single-ended: 10 kohm, 50 ohm, 37.5 ohm
Differential: 10 kohm, 100 ohm
Differential center GND: 100 ohm, 75 ohm
15 MHz (Fixed anti-aliasing analog filter, nominal value)
Digital filter: 6.1 MHz, 13 MHz
Lesson 1 – Analog Modules