electrical characteristics over recommended operating free-air temperature range, AV
= 20 mA, single-ended output IOUT1, 50 Ω doubly terminated load (unless
DV
= 5 V, IOUT
DD
FS
otherwise noted)
ac specifications
PARAMETER
Analog output
f CLK
Maximum output update rate
p
p
Output settling time to 0.1% †
t s(DAC)
t pd
Output propagation delay
Glitch energy ‡
GE
Output rise time 10% to 90% †
t r(IOUT)
Output fall time 90% to 10% †
t f(IOUT)
Output noise
p
AC linearity (to Nyquist)
SINAD
Signal-to-noise and distortion ratio
THD
Total harmonic distortion
† Measured single ended into 50 Ω load at IOUT1.
‡ Single-ended output IOUT1, 50 Ω doubly terminated load.
TEST CONDITIONS
DV DD = 4.5 V to 5.5 V
DV DD = 3 V to 3.6 V
Worst case LSB transition (code 127 – code 128)
IOUT FS = 20 mA
IOUT FS = 2 mA
f CLK = 5 MSPS, f OUT = 1 MHz, T A = 25°C
f CLK = 25 MSPS, f OUT = 1 MHz, T A = 25°C
f CLK = 25 MSPS, f OUT = 5 MHz, T A = 25°C
f CLK = 25 MSPS, f OUT = 10 MHz, T A = 25°C
f CLK = 50 MSPS, f OUT = 1 MHz, T A = 25°C
f CLK = 50 MSPS, f OUT = 5 MHz, T A = 25°C
f CLK = 50 MSPS, f OUT = 20 MHz, T A = 25°C
f CLK = 70 MSPS, f OUT = 5 MHz, T A = 25°C
f CLK = 70 MSPS, f OUT = 10 MHz, T A = 25°C
f CLK = 70 MSPS, f OUT = 20 MHz, T A = 25°C
f CLK = 100 MSPS, f OUT = 10 MHz, T A = 25°C
f CLK = 100 MSPS, f OUT = 22 MHz, T A = 25°C
f CLK = 100 MSPS, f OUT = 40 MHz, T A = 25°C
f CLK = 5 MSPS, f OUT = 1 MHz, T A = 25°C
f CLK = 25 MSPS, f OUT = 1 MHz, T A = 25°C
f CLK = 25 MSPS, f OUT = 5 MHz, T A = 25°C
f CLK = 25 MSPS, f OUT = 10 MHz, T A = 25°C
f CLK = 50 MSPS, f OUT = 1 MHz, T A = 25°C
f CLK = 50 MSPS, f OUT = 1 MHz, T A = –40°C to 85°C
f CLK = 50 MSPS, f OUT = 5 MHz, T A = 25°C
f CLK = 50 MSPS, f OUT = 20 MHz, T A = 25°C
f CLK = 70 MSPS, f OUT = 5 MHz, T A = 25°C
f CLK = 70 MSPS, f OUT = 10 MHz, T A = 25°C
f CLK = 70 MSPS, f OUT = 20 MHz, T A = 25°C
f CLK = 100 MSPS, f OUT = 10 MHz, T A = 25°C
f CLK = 100 MSPS, f OUT = 22 MHz, T A = 25°C
f CLK = 100 MSPS, f OUT = 40 MHz, T A = 25°C
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
8-BIT, 100 MSPS, CommsDAC
Appendix C
DIGITAL-TO-ANALOG CONVERTER
SLAS277A –MARCH 2000 – REVISED SEPTEMBER 2002
MIN
TYP
100
67
35
15
10
50
50
50
48
50
50
47
50
50
46
47
47
45
–69
–67
–69
–57
–67
–66
–52
–64
–60
–48
–53
–53
–47
THS5641A
= 5 V,
DD
MAX
UNIT
MSPS
ns
1
ns
5
pV–s
1
ns
1
ns
pA/√HZ
dB
–64
dBc
591