Mixed-signal training
Hide thumbs Also See for 93000 SOC Series:
Table of Contents

Advertisement

Lesson 3 – Setting Up the Digital Capturing
NOTE
The syntax for using 14 edges, is shown in the following example:
Selective Capture Timing Syntax
In the following section you will see an example of how to use the
capture/do not capture waveforms in a vector label.
When defining selective capture actions (C and D actions) in a wave
table, some capabilities of the Device Cycle Expander will be used
internally. A free Device Cycle Expander table will be allocated to
every wave table using selective capture actions.
Therefore, you have to make sure that
number of wave tables using selective capture actions +1
Device Cycle Expander sets are available in the system.
Adjusting the Number of PDC Sets
When loading a timing that requires more than the currently
defined Device Cycle Expander sets, the following error message
will be displayed: