Agilent Technologies 93000 SOC Series Training Manual page 114

Mixed-signal training
Hide thumbs Also See for 93000 SOC Series:
Table of Contents

Advertisement

Lesson 1 – Analog Modules
Specification
Pin counts
Voltage Force:
V Source in Source Unit or Measure Unit
Table 24
MCA V Source Key Specifications
Value
4 (one at a time) per source unit or measure unit.
Range
For Source Unit (SRCA):
For Measure Unit (MESA):
Resolution
0.1 mV
±0.1% of setting ±5mV @ ≥ 10 kohm load to GND
Accuracy
fied. With the specified value, the software applies the correc-
tion of the voltage across the output impedance (52 ohm
nominal). If the specified load impedance value differs from the
true value by x%, an additional error of x/(1 + Z/52) % occurs,
where Z is the true load impedance. For example, when Z = 10
kohm and x = ±1%, add ±0.0052% of setting.
Output current range
±3 mA
114
8 source or measure units in module
±3.5 V @ ≥ 10 kohm load to GND
±3 V @ ≥ 10 kohm load to GND
This accuracy is when the load impedance value is speci-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents