E R R O R S
in
ERROR: line X: No more set space ("Y"). CAPTURE
cannot be defined
Setting up the Vectors
As mentioned before, the device input vectors for Digital Capture
must reside in the sequencer memory.
Creating a Vector Label
You can set up a vector label for Digital Capture with the vector
editor like any other label, but the following two rules must be
followed:
The label must be a main label.
•
The sequencer memory (SM) must be chosen as the location for the
•
vectors.
select
main
Creating a Vector Label for Digital Capture
Entering the Vectors
After a main vector label for Digital Capture has been defined, you
can enter in the Vector Editor the actual vectors which contain the
input data of the device and the expected output data.
There are some special aspects which should always be considered
when setting up vectors for Digital Capture:
In General:
An efficient way to capture a large number of samples is to use
•
loops and REPEAT commands in the vector label.
Lesson 3 – Setting Up the Digital Capturing
"WAVE TABLES"
select
SM
333