Sign In
Upload
Manuals
Brands
Delta Manuals
UPS
Modulon DPH series
Delta Modulon DPH series Manuals
Manuals and User Guides for Delta Modulon DPH series. We have
8
Delta Modulon DPH series manuals available for free PDF download: User Manual
Delta Modulon DPH series User Manual (268 pages)
Three Phase, 100-300 kVA
Brand:
Delta
| Category:
UPS
| Size: 18.89 MB
Table of Contents
Table of Contents
3
1 Important Safety Instructions
9
Installation Warnings
10
Connection Warnings
10
Usage Warnings
11
Storage Warnings
13
Standard Compliance
13
2 Introduction
15
General Overview
16
Package Inspection
16
Functions & Features
18
Exterior and Dimensions
20
Front View
21
Internal View
22
Rear View
24
Tri-Color LED Indicator & Buzzer
27
3 Operation Modes
31
Single Input
32
On-Line Mode_ Single Input_ Single Unit
32
Battery Mode_ Single Input_ Single Unit
33
Bypass Mode_ Single Input_ Single Unit
34
Manual Bypass Mode_ Single Input_ Single Unit
34
ECO Mode_ Single Input_ Single Unit
36
Frequency Conversion Mode_ Single Input_ Single Unit
36
Green Mode_ Single Input_ Single Unit
37
Energy Recycle Mode_ Single Input_ Single Unit
38
On-Line Mode_ Single Input_ Parallel Units
39
Battery Mode_ Single Input_ Parallel Units
40
Bypass Mode_ Single Input_ Parallel Units
41
Manual Bypass Mode_ Single Input_ Parallel Units
42
ECO Mode_ Single Input_ Parallel Units
44
Green Mode_ Single Input_ Parallel Units
45
Dual Input
46
On-Line Mode_ Dual Input_ Single Unit
46
Battery Mode_ Dual Input_ Single Unit
46
Bypass Mode_ Dual Input_ Single Unit
47
Manual Bypass Mode_ Dual Input_ Single Unit
48
ECO Mode_ Dual Input_ Single Unit
49
Frequency Conversion Mode_ Dual Input_ Single Unit
50
Green Mode_ Dual Input_ Single Unit
51
On-Line Mode_ Dual Input_ Parallel Units
52
Battery Mode_ Dual Input_ Parallel Units
53
Bypass Mode_ Dual Input_ Parallel Units
54
Manual Bypass Mode_ Dual Input_ Parallel Units
55
ECO Mode_ Dual Input_ Parallel Units
57
Green Mode_ Dual Input_ Parallel Units
58
Hot Standby Redundancy (Only for Dual Input & at Least Two Upss)
59
Common Battery
60
The same External Battery Cabinet
60
4 Communication Interfaces
63
Communication Interfaces on the Front of the UPS with Front Door Open
64
Display Port
65
REPO Dry Contacts
66
External Battery Temperature Dry Contacts
67
External Switch/ Breaker Status Dry Contacts
68
Output Dry Contacts
69
Input Dry Contacts
72
Parallel Communication Cards
73
Parallel Ports
74
SMART Slot
74
USB Port & RS-232 Port
75
Auxiliary Power Cards
75
Battery Start Buttons
76
Communication Interfaces at the Rear of the Touch Panel
76
5 Installation and Wiring
79
Before Installation and Wiring
80
Installation Environment
80
UPS Transportation
82
Fixing the UPS
83
Wiring
85
Pre-Wiring Warnings
85
Single Unit Wiring
91
Parallel Unit Wiring
100
External Battery Cabinet Connection Warnings
104
STS Module
111
STS Module Installation
112
STS Module Removal
114
STS Module's LED Indicator
116
Power Module (Optional)
117
Power Module Installation
118
Power Module Removal
120
Power Module's LED Indicator
123
6 UPS Operation
125
Parallel Units
126
Start-Up Procedures
128
On-Line Mode Start-Up Procedures
128
Battery Mode Start-Up Procedures
132
Bypass Mode Start-Up Procedures
134
Manual Bypass Mode Start-Up Procedures
137
ECO Mode Start-Up Procedures
142
Frequency Conversion Mode Start-Up Procedures
146
Green Mode Start-Up Procedures
149
Energy Recycle Mode Start-Up Procedures
153
System Status
162
Mins
163
Switch off the Input Breaker (Q1), Bypass Breaker (Q2) and Output Breaker (Q4)
163
About 3 Minutes Later, the UPS will Shut Down, and the LCD and the Tri-Color LED
164
Switch off Every External Battery Cabinet's Breaker (Q5)
164
SETUP MAINTENANCE LOG in User
165
Power off
165
Transfer to Bypass Without Protection
165
Yes no
165
Standby
165
May 25,2018
168
User
168
Event Log Eco
169
Advertisement
Delta Modulon DPH series User Manual (250 pages)
Brand:
Delta
| Category:
UPS
| Size: 19.63 MB
Table of Contents
Table of Contents
3
1 Important Safety Instructions
7
Installation Warnings
8
Connection Warnings
8
Usage Warnings
10
Storage Warnings
11
Standard Compliance
12
2 Introduction
13
General Overview
14
Package Inspection
14
Functions & Features
15
Exterior and Dimensions
17
Front View
18
Internal View
19
Rear View
23
Tri-Color LED Indicator & Buzzer
24
3 Operation Modes
27
Single Input
28
On-Line Mode_ Single Input_ Single Unit
28
Battery Mode_ Single Input_ Single Unit
29
Bypass Mode_ Single Input_ Single Unit
30
Manual Bypass Mode_ Single Input_ Single Unit
30
ECO Mode_ Single Input_ Single Unit
32
Frequency Conversion Mode_ Single Input_ Single Unit
32
Green Mode_ Single Input_ Single Unit
33
Energy Recycle Mode_ Single Input_ Single Unit
34
On-Line Mode_ Single Input_ Parallel Units
35
Battery Mode_ Single Input_ Parallel Units
36
Bypass Mode_ Single Input_ Parallel Units
37
Manual Bypass Mode_ Single Input_ Parallel Units
38
ECO Mode_ Single Input_ Parallel Units
40
Green Mode_ Single Input_ Parallel Units
41
Dual Input
42
Battery Mode_ Dual Input_ Single Unit
42
On-Line Mode_ Dual Input_ Single Unit
42
Bypass Mode_ Dual Input_ Single Unit
43
Manual Bypass Mode_ Dual Input_ Single Unit
44
ECO Mode_ Dual Input_ Single Unit
45
Frequency Conversion Mode_ Dual Input_ Single Unit
46
Green Mode_ Dual Input_ Single Unit
47
On-Line Mode_ Dual Input_ Parallel Units
48
Battery Mode_ Dual Input_ Parallel Units
49
Bypass Mode_ Dual Input_ Parallel Units
50
Manual Bypass Mode_ Dual Input_ Parallel Units
51
ECO Mode_ Dual Input_ Parallel Units
53
Green Mode_ Dual Input_ Parallel Units
54
Hot Standby Redundancy (Only for Dual Input & at Least Two Upss)
55
Common Battery
56
External Battery Cabinet
56
4 Communication Interfaces
59
Communication Interfaces on the Front of the UPS with Front Door Open
60
Display Port
62
REPO Dry Contacts
62
External Battery Temperature Dry Contacts
63
External Switch/ Breaker Status Dry Contacts
64
Output Dry Contacts
64
Input Dry Contacts
67
Parallel Communication Card
68
Parallel Ports
69
SMART Slot
70
USB Port & RS-232 Port
70
Auxiliary Power Cards
71
Battery Start Buttons
71
Routing for REPO Port, Dry Contacts, Parallel Ports, USB Port & RS-232 Port
72
Communication Interfaces at the Rear of the Touch Panel
75
5 Installation and Wiring
77
Before Installation and Wiring
78
Installation Environment
78
UPS Transportation
80
Fixing the UPS
81
Wiring
83
Pre-Wiring Warnings
83
Single Unit Wiring
88
Parallel Unit Wiring
94
External Battery Cabinet Connection Warnings
98
STS Module
105
STS Module Installation
106
STS Module Removal
108
STS Module's LED Indicator
110
Power Module (Optional)
111
Power Module Installation
112
Power Module Removal
115
Power Module's LED Indicator
117
6 UPS Operation
119
Start-Up Procedures
122
On-Line Mode Start-Up Procedures
122
Battery Mode Start-Up Procedures
125
Bypass Mode Start-Up Procedures
128
Manual Bypass Mode Start-Up Procedures
131
ECO Mode Start-Up Procedures
136
Frequency Conversion Mode Start-Up Procedures
140
Green Mode Start-Up Procedures
144
Energy Recycle Mode Start-Up Procedures
148
7 LCD Display & Settings
169
LCD Display Hierarchy
170
How to Turn on the LCD
171
ON/ off Button
173
Ups-1.1 Measurement
173
Introduction of Touch Panel and Function Keys
175
Power Flow
175
Battery
177
Summary
177
Di1 ~ Di4
177
Ems
177
Load
178
Main Screen
180
Password Entry
180
Main Menu
184
Delta Modulon DPH series User Manual (256 pages)
Three Phase 200-600 kVA
Brand:
Delta
| Category:
UPS
| Size: 13.48 MB
Table of Contents
Table of Contents
3
1 Important Safety Instructions
7
Installation Warnings
8
Connection Warnings
8
Usage Warnings
9
Storage Warnings
11
Standard Compliance
11
2 Introduction
13
General Overview
14
Package Inspection
14
Functions & Features
16
Exterior & Dimensions
18
Front View
18
Internal View
19
Rear View
23
Tri-Color LED Indicator & Buzzer
24
3 Operation Modes
27
Single Input
28
On-Line Mode_ Single Input_ Single Unit
28
Battery Mode_ Single Input_ Single Unit
29
Bypass Mode_ Single Input_ Single Unit
30
Manual Bypass Mode_ Single Input_ Single Unit
30
ECO Mode_ Single Input_ Single Unit
32
Frequency Conversion Mode_ Single Input_ Single Unit
32
Green Mode_ Single Input_ Single Unit
33
Energy Recycle Mode_ Single Input_ Single Unit
34
On-Line Mode_ Single Input_ Parallel Units
35
Battery Mode_ Single Input_ Parallel Units
36
Bypass Mode_ Single Input_ Parallel Units
37
Manual Bypass Mode_ Single Input_ Parallel Units
38
ECO Mode_ Single Input_ Parallel Units
40
Green Mode_ Single Input_ Parallel Units
41
Dual Input
42
On-Line Mode_ Dual Input_ Single Unit
42
Battery Mode_ Dual Input_ Single Unit
42
Bypass Mode_ Dual Input_ Single Unit
43
Manual Bypass Mode_ Dual Input_ Single Unit
44
ECO Mode_ Dual Input_ Single Unit
45
Frequency Conversion Mode_ Dual Input_ Single Unit
46
Green Mode_ Dual Input_ Single Unit
47
On-Line Mode_ Dual Input_ Parallel Units
48
Battery Mode_ Dual Input_ Parallel Units
49
Bypass Mode_ Dual Input_ Parallel Units
50
Manual Bypass Mode_ Dual Input_ Parallel Units
51
ECO Mode_ Dual Input_ Parallel Units
53
Green Mode_ Dual Input_ Parallel Units
54
Hot Standby Redundancy (Only for Dual Input & at Least Two Upss)
55
Common Battery
56
External Battery Cabinet
56
4 Communication Interfaces
59
Communication Interfaces on the Front of the UPS with Two Front Doors Open
60
Display Port
62
REPO Dry Contacts
62
External Battery Temperature Dry Contacts
63
External Switch/ Breaker Status Dry Contacts
63
Output Dry Contacts
65
Input Dry Contacts
67
Parallel Communication Cards
68
Parallel Ports
69
SMART Slot
69
USB Port & RS-232 Port
70
Auxiliary Power Cards
70
Battery Start Buttons
71
Communication Interfaces at the Rear of the Touch Panel
71
5 Installation and Wiring
73
Before Installation and Wiring
74
Installation Environment
74
UPS Transportation
76
Fixing the UPS
76
Wiring
78
Pre-Wiring Warnings
78
Single Unit Wiring
83
Parallel Units Wiring
88
External Battery Cabinet Connection Warnings
92
STS Module
98
STS Module Installation
99
STS Module Removal
102
STS Module's LED Indicator
104
Power Module (Optional)
105
Power Module Installation
105
Power Module Removal
108
Power Module's LED Indicator
110
6 UPS Operation
111
Start-Up Procedures
114
On-Line Mode Start-Up Procedures
114
Battery Mode Start-Up Procedures
118
Bypass Mode Start-Up Procedures
120
Manual Bypass Mode Start-Up Procedures
123
ECO Mode Start-Up Procedures
128
Frequency Conversion Mode Start-Up Procedures
132
Green Mode Start-Up Procedures
135
Energy Recycle Mode Start-Up Procedures
139
Mins
147
Switch off the Input Switch (Q1), Bypass Switch (Q2) and Output Switch (Q4)
149
About 3 Minutes Later, the UPS will Shut Down, and the LCD and Tri-Color LED Indicator
150
Switch off Every External Battery Cabinet's Breaker (Q5)
150
Advertisement
Delta Modulon DPH series User Manual (232 pages)
200-500 kVa , Three phase
Brand:
Delta
| Category:
UPS
| Size: 9.86 MB
Table of Contents
Table of Contents
3
1 Important Safety Instructions
7
Installation Warnings
8
Connection Warnings
8
Usage Warnings
10
Storage Warnings
12
Standard Compliance
12
2 Introduction
13
General Overview
14
Package Inspection
14
Functions & Features
16
Exterior and Dimensions
18
Front View
18
Internal View
20
Rear View
21
Tri-Color LED Indicator & Buzzers
23
3 Operation Modes
27
Single Input
30
Online Mode_ Single Input_ Single Unit
30
Battery Mode_ Single Input_ Single Unit
31
Bypass Mode_ Single Input_ Single Unit
32
Manual Bypass Mode_ Single Input_ Single Unit
32
ECO Mode_ Single Input_ Single Unit
34
Frequency Conversion Mode_ Single Input_ Single Unit
34
Green Mode _ Single Input_ Single Unit
35
Energy Recycle Mode _ Single Input_ Single Unit
36
Online Mode_ Single Input_ Parallel Units
37
Battery Mode _ Single Input_ Parallel Units
38
Bypass Mode_ Single Input_ Parallel Units
39
Manual Bypass Mode_ Single Input_ Parallel Units
40
ECO Mode_ Single Input_ Parallel Units
42
Frequency Conversion Mode_ Single Input_ Parallel Units
43
Green Mode_ Single Input_ Parallel Units
44
Dual Input
45
Online Mode_ Dual Input_ Single Unit
45
Battery Mode_ Dual Input_ Single Unit
45
Bypass Mode_ Dual Input_ Single Unit
46
Manual Bypass Mode_ Dual Input_ Single Unit
47
ECO Mode_ Dual Input_ Single Unit
48
Frequency Conversion Mode_ Dual Input_ Single Unit
49
Green Mode _ Dual Input_ Single Unit
50
Online Mode_ Dual Input_ Parallel Units
51
Battery Mode _ Dual Input_ Parallel Units
52
Bypass Mode_ Dual Input_ Parallel Units
53
Manual Bypass Mode_ Dual Input_ Parallel Units
54
ECO Mode_ Dual Input_ Parallel Units
56
Frequency Conversion Mode_ Single Input_ Parallel Units
57
Green Mode_ Dual Input_ Parallel Units
58
Hot Standby Redundancy (Only for Dual Input & at Least Two Upss)
59
Common Battery
60
The same External Battery Cabinet
60
4 Communication Interfaces
63
Communication Interfaces on the Front of the UPS with Front Door Open
64
Display Port
65
REPO Dry Contacts
65
External Battery Temperature Dry Contacts
67
External Switch/ Breaker Status Dry Contacts
68
Output Dry Contacts
69
Input Dry Contacts
72
Parallel Communication Cards
73
Parallel Ports
73
SMART Slot
74
USB Port & RS-232 Port
74
Auxiliary Power Cards
74
Battery Start Buttons
75
Communication Interfaces at the Rear of the Touch Panel
75
5 Installation and Wiring
77
Before Installation and Wiring
78
Installation Environment
79
UPS Transportation
81
Fixing the UPS
82
Wiring
84
Pre-Wring Warnings
84
Single Input/ Dual Input Modification
86
Single Unit Wiring
88
Parallel Units Wiring
97
External Battery Cabinet Connection Warnings
101
STS Module
108
STS Module Installation
109
STS Module Removal
111
STS Module's LED Indicator
113
Power Module (Optional)
113
Power Module Installation
114
Power Module Removal
116
Power Module's LED Indicator
118
6 UPS Operation
119
Pre Start-Up & Pre Turn-Off Warnings for Single Unit
120
And Parallel Units
120
Start-Up Procedures
122
Online Mode Start-Up Procedures
122
Battery Mode Start-Up Procedures
126
Bypass Mode Start-Up Procedures
128
Manual Bypass Mode Start-Up Procedures
131
ECO Mode Start-Up Procedures
136
Frequency Conversion Mode Start-Up Procedures
140
Green Mode Start-Up Procedures
144
Energy Recycle Mode Start-Up Procedures
148
Turn-Off Procedures
152
Online Mode Turn-Off Procedures
152
Battery Mode Turn-Off Procedures
154
Bypass Mode Turn-Off Procedures
156
Manual Bypass Mode Turn-Off Procedures
157
ECO Mode Turn-Off Procedures
157
Frequency Conversion Mode Turn-Off Procedures
160
Green Mode Turn-Off Procedures
163
10:15 2 May 25,2018
163
Warning
163
System Status
164
Mins
164
Dual Input
165
Breaker or Switch (Q4)
165
Energy Recycle Mode Turn-Off Procedures
166
Now, each Power Module Performs DC BUS Discharging and Its LED Indicator Flashes Green. after Discharging, each Power Module's LED Indicator will be off
166
About 3 Minutes Later, the UPS will Shut Down. after That, the LCD and the Tricolor LED
166
Indicator will be off
166
Switch off Every External Battery Cabinet's Breaker (Q5)
166
Delta Modulon DPH series User Manual (228 pages)
Three Phase 15-60 kVA 208Vac
Brand:
Delta
| Category:
UPS
| Size: 18.96 MB
Table of Contents
Table of Contents
3
1 Important Safety Instructions
7
Installation Warnings
8
Connection Warnings
8
Usage Warnings
10
Storage Warnings
11
Standard Compliance
11
2 Introduction
13
General Overview
14
Package Inspection
14
Functions & Features
16
Exterior and Dimensions
18
Front View
18
Internal View
20
Rear View
24
Tri-Color LED Indicator & Buzzer
25
3 Operation Modes
27
Single Input
28
Online Mode_ Single Input_ Single Unit
28
Battery Mode_ Single Input_ Single Unit
29
Bypass Mode_ Single Input_ Single Unit
29
Manual Bypass Mode_ Single Input_ Single Unit
30
ECO Mode_ Single Input_ Single Unit
31
Frequency Conversion Mode_ Single Input_ Single Unit
31
Green Mode_ Single Input_ Single Unit
32
Energy Recycle Mode_ Single Input_ Single Unit
33
Online Mode_ Single Input_ Parallel Units
34
Battery Mode_ Single Input_ Parallel Units
35
Bypass Mode_ Single Input_ Parallel Units
36
Manual Bypass Mode_ Single Input_ Parallel Units
37
ECO Mode_ Single Input_ Parallel Units
39
Frequency Conversion Mode_ Single Input_ Parallel Units
40
Dual Input
41
Battery Mode_ Dual Input_ Single Unit
41
Online Mode_ Dual Input_ Single Unit
41
Bypass Mode_ Dual Input_ Single Unit
42
Manual Bypass Mode_ Dual Input_ Single Unit
43
ECO Mode_ Dual Input_ Single Unit
44
Frequency Conversion Mode_ Dual Input_ Single Unit
45
Green Mode_ Dual Input_ Single Unit
46
Online Mode_ Dual Input_ Parallel Units
47
Battery Mode_ Dual Input_ Parallel Units
48
Bypass Mode_ Dual Input_ Parallel Units
49
Manual Bypass Mode_ Dual Input_ Parallel Units
50
ECO Mode_ Dual Input_ Parallel Units
52
Frequency Conversion Mode_ Dual Input_ Parallel Units
53
Hot Standby Redundancy (Only for Dual Input & at Least Two Upss)
54
Common Battery
55
4 Communication Interfaces
57
Communication Interfaces on the Front of the UPS with Front Door Open
58
Display Port
59
REPO Dry Contacts
60
External Battery Temperature Dry Contacts
61
External Switch/ Breaker Status Dry Contacts
62
Output Dry Contacts
63
Input Dry Contacts
66
Parallel Communication Cards
67
Parallel Ports
67
Auxiliary Power Cards
68
SMART Slot
68
USB Port & RS-232 Port
68
Battery Start Buttons
69
Communication Interfaces at the Rear of the Touch Panel
69
5 Installation and Wiring
71
Before Installation and Wiring
72
Installation Environment
72
UPS Transportation
73
Fixing the UPS
74
Wiring
76
Pre-Wiring Warnings
76
Single Unit Wiring
81
Parallel Units Wiring
88
External Battery Cabinet Connection Warnings
91
STS Module
96
STS Module Installation
97
STS Module Removal
98
STS Module's LED Indicator
100
Power Module (Optional)
101
Power Module Installation
101
Power Module Removal
104
Power Module's LED Indicator
106
Battery Module (Optional)
107
Battery Module Warnings
108
Battery Module Installation
109
Battery Module Removal
112
Battery Module's LED Indicator
113
6 UPS Operation
115
Start-Up Procedures
118
Online Mode Start-Up Procedures
118
Battery Mode Start-Up Procedures
122
Bypass Mode Start-Up Procedures
124
Manual Bypass Mode Start-Up Procedures
127
ECO Mode Start-Up Procedures
131
Frequency Conversion Mode Start-Up Procedures
135
Green Mode Start-Up Procedures
139
Energy Recycle Mode Start-Up Procedures
142
Switch off the Input/ Bypass Breaker (Q1) and Output Breaker (Q3). after That, the Ups will Run in Standby Mode/About 3 Minutes Later, the Ups will Shut down and the LCD and the Tri-Color Led
147
10:15 May 25,2018
150
Log in
150
Maintenance
150
Setup
150
User
150
EVENT LOG Bypass
152
Switch off the Input/ Bypass Breaker (Q1) and Output Breaker (Q3). after That, the UPS will Run in Standby Mode
153
About 3 Minutes Later, the UPS will Shut down and the LCD and the Tri-Color LED
156
7 LCD Display & Settings
163
Delta Modulon DPH series User Manual (232 pages)
Three Phase 200-600 kVA
Brand:
Delta
| Category:
UPS
| Size: 12.95 MB
Table of Contents
Table of Contents
3
Important Safety Instructions
7
Installation Warnings
8
Connection Warnings
8
Usage Warnings
9
Storage Warnings
11
Standard Compliance
11
Introduction
13
General Overview
14
Package Inspection
14
Functions & Features
16
Exterior & Dimensions
17
Front View
18
Internal View
19
Rear View
22
Tri-Color LED Indicator & Buzzer
23
Operation Modes
27
Single Input
28
On-Line Mode_ Single Input_ Single Unit
28
Battery Mode_ Single Input_ Single Unit
29
Bypass Mode_ Single Input_ Single Unit
29
Manual Bypass Mode_ Single Input_ Single Unit
30
ECO Mode_ Single Input_ Single Unit
31
Frequency Conversion Mode_ Single Input_ Single Unit
32
Green Mode_ Single Input_ Single Unit
32
Energy Recycle Mode_ Single Input_ Single Unit
33
On-Line Mode_ Single Input_ Parallel Units
34
Battery Mode_ Single Input_ Parallel Units
35
Bypass Mode_ Single Input_ Parallel Units
36
Manual Bypass Mode_ Single Input_ Parallel Units
37
ECO Mode_ Single Input_ Parallel Units
39
Green Mode_ Single Input_ Parallel Units
40
Dual Input
41
On-Line Mode_ Dual Input_ Single Unit
41
Battery Mode_ Dual Input_ Single Unit
42
Bypass Mode_ Dual Input_ Single Unit
42
Manual Bypass Mode_ Dual Input_ Single Unit
43
ECO Mode_ Dual Input_ Single Unit
44
Frequency Conversion Mode_ Dual Input_ Single Unit
45
Green Mode_ Dual Input_ Single Unit
46
On-Line Mode_ Dual Input_ Parallel Units
46
Battery Mode_ Dual Input_ Parallel Units
48
Bypass Mode_ Dual Input_ Parallel Units
49
Manual Bypass Mode_ Dual Input_ Parallel Units
50
ECO Mode_ Dual Input_ Parallel Units
52
Green Mode_ Dual Input_ Parallel Units
53
Hot Standby Redundancy (Only for Dual Input & at Least Two Upss)
54
Common Battery
55
External Battery Cabinet
55
Communication Interfaces
57
Communication Interfaces (I): on the Front of the UPS with Two Front Doors Open
57
Display Port
60
REPO Dry Contacts
60
External Battery Temperature Detection
61
External Switch/ Breaker Status Dry Contacts
61
Output Dry Contacts
63
Input Dry Contacts
65
Parallel Communication Cards
66
Parallel Ports
67
SMART Slot
67
USB Port & RS-232 Port
68
Auxiliary Power Cards
69
Battery Start Buttons
69
Communication Interfaces (II): at the Rear of the Touch Panel
70
Installation and Wiring
71
Before Installation and Wiring
72
Installation Environment
72
UPS Transportation
74
UPS Installation
74
Wiring
76
Pre-Wiring Warnings
76
Single Unit Wiring
81
Parallel Units Wiring
89
External Battery Cabinet Connection Warnings
94
STS Module
100
STS Module Installation
101
STS Module Removal
103
STS Module's LED Indicator
106
Power Module (Optional)
106
Power Module Installation
107
Power Module Removal
110
Power Module's LED Indicator
112
UPS Operation
113
Start-Up Procedures
116
On-Line Mode Start-Up Procedures
116
Battery Mode Start-Up Procedures
120
Bypass Mode Start-Up Procedures
122
Manual Bypass Mode Start-Up Procedures
125
ECO Mode Start-Up Procedures
130
Frequency Conversion Mode Start-Up Procedures
134
Green Mode Start-Up Procedures
137
Energy Recycle Mode Start-Up Procedures
141
LCD Display & Settings
161
LCD Display Hierarchy
162
How to Turn on the LCD
163
ON/ off Button
165
Introduction of Touch Panel and Function Keys
167
Password Entry
173
Main Screen
173
Main Menu
177
Power Flow, Summary, System Status & EMS
179
Check System Readings
181
Main Input
181
Check Kilowatt-Hour
182
Bypass Input
183
Inverter Output
184
Power Module Summary
184
Delta Modulon DPH series User Manual (240 pages)
Three Phase 100-300 kVA
Brand:
Delta
| Category:
UPS
| Size: 18.23 MB
Table of Contents
Table of Contents
149
10:15 May 25,2018
151
Mains
151
System Status
151
Mins
151
Ems
151
Warning
153
For Parallel Units, Ensure that Every Operation Procedure Mentioned below Is Synchronized to All Parallel Upss
156
Parallel Ones, Please Contact Service Personnel
156
LCD Display Hierarchy
174
Measurement
180
Ups-1.1
180
Power Module Summary
190
Di1 ~ Di4
199
Ems
199
Temperature Humidity DI1 ~ DI4
201
Setup
202
Bypass Frequency Range
203
Bypass Setting
203
ECO Voltage Range
203
Frequency Conversion
204
Mode Setting
204
Output Setting
204
Module Sequential Start (S)
205
PM Redundancy (V)
205
System Sequential Start (S)
205
Voltage (V)/ Voltage Compensation (V)
205
Battery & Charging Setting
206
Battery Type/ Battery Rating Voltage
206
Auto Equalized Charge
208
Auto Equalized Charge Interval
208
Battery Test Fail Voltage
208
Charge Current (Max)
208
Equalized Charge Time
208
Float Charge Voltage
208
Auto Battery Test Interval
209
Battery Test Duration
209
High Temperature Alarm
209
Low Temperature Alarm
209
Parallel Group ID Parallel ID
209
Parallel Setting
209
Common Battery
210
Dry Contact Setting
210
Input Dry Contact: 1
210
Output Dry Contact: 1
211
General Setting
212
Date/ Time
213
Language Admin Password
213
Screen
213
Dust Filter
214
Dust Filter Replacement Date
214
Modbus ID
214
DHCP Client/ IP Address/ Subnet Mask
215
IP Setting
215
MODBUS ID/ MODBUS Baud Rate
215
Search Domain Host Name
215
Control
216
EMS Setting
217
Force Bypass to Inverter
217
Force Equalized Charge
217
Input Contact: 1
218
Sensor
218
Historical Event Log-In ID
219
NC/ Event Type
219
Warning
219
Warning Log-In ID
219
Administrator
220
Historical Event
220
Battery Mode Duration
221
Bypass Mode Duration
221
In Battery Mode
221
In Bypass Mode
221
Operation Time
221
Statistics
221
Clear
222
Manual Battery Test
222
Test
222
Advanced Diagnosis
223
Battery Temp. (°C)
223
Clear Battery Test Result
223
Clear Historical Event
223
Clear Kilowatt Hour (Kwh)
223
Clear Statistics
223
Fan Speed (Rpm)
223
STS Temp. (°C)
223
INV Temp. (°C)
224
PFC Temp. (°C)
224
Power Module 01
224
System
224
Touch Panel
224
Version & S/N
224
Inv
226
Main
226
Mfc Mcu
226
Parallel Communication Card #N_ MCU/ FPGA
226
Pfc
226
Power Module
226
System Control Card_ MCU/ FPGA
226
Touch Panel
226
Delta Modulon DPH series User Manual (148 pages)
Brand:
Delta
| Category:
UPS
| Size: 9.36 MB
Table of Contents
Table of Contents
3
Chapter 1 : Important Safety Instructions
7
Installation Warnings
7
Connection Warnings
7
1.3 Usage Warnings
9
Storage Warnings
11
Standard Compliance
11
Chapter 2 : Introduction
12
General Overview
12
Package Inspection
12
Functions & Features
13
Exterior & Dimensions
15
Front View
15
Internal View
16
Tri-Color LED Indicator & Buzzer
19
Chapter 3 : Operation Modes
21
On-Line Mode
21
Battery Mode
22
Bypass Mode
23
Manual Bypass Mode
23
ECO Mode
24
Frequency Conversion Mode
24
Green Mode
25
Chapter 4 : Communication Interfaces
26
Communication Interfaces I: on the Front of the System Cabinet with Its Front Door Open
26
Display Port
27
REPO Dry Contacts
27
External Battery Temperature Detection
28
External Switch/ Breaker Status Dry Contacts
29
Output Dry Contacts
30
Input Dry Contacts
33
Parallel Communication Cards
34
Parallel Ports
35
SMART Slot
35
4.1.10 USB Port & RS-232 Port
36
4.1.11 Auxiliary Power Cards
36
4.1.12 Battery Start Buttons
37
Communication Interfaces II: at the Rear of the Touch Panel
37
Cable Routing for the Communication Interfaces
38
Chapter 5 : Installation and Wiring
39
Before Installation and Wiring
39
Installation Environment
39
UPS Installation
41
Wiring
48
Pre-Wiring Warnings
48
Single Input to Dual Input Modification
56
Single Unit Wiring
57
Single Input (Single Unit)
59
Dual Input (Single Unit)
64
Parallel Units Wiring
65
External Battery Cabinet Connection Warnings
67
STS Module
74
STS Module Installation
75
STS Module Removal
78
STS Module's LED Indicator
80
Power Module (Optional)
80
Power Module Installation
81
Power Module Removal
84
Power Module's LED Indicator
86
Auxiliary Module
86
Auxiliary Module Installation
87
Auxiliary Module Removal
88
Auxiliary Module's LED Indicator
90
Chapter 6 : UPS Operation
91
Pre Start-Up & Pre Turn-Off Warnings
91
Start-Up Procedures
92
On-Line Mode Start-Up Procedures
92
Battery Mode Start-Up Procedures
93
Bypass Mode Start-Up Procedures
94
Manual Bypass Mode Start-Up Procedures
95
ECO Mode Start-Up Procedures
97
Frequency Conversion Mode Start-Up Procedures
99
Green Mode Start-Up Procedures
101
Turn-Off Procedures
103
On-Line Mode Turn-Off Procedures
103
Battery Mode Turn-Off Procedures
103
Bypass Mode Turn-Off Procedures
104
Manual Bypass Mode Turn-Off Procedures
104
ECO Mode Turn-Off Procedures
104
Frequency Conversion Mode Turn-Off Procedures
105
Green Mode Turn-Off Procedures
105
Start-Up & Turn off Procedures for Parallel Units
106
Advertisement
Related Products
Delta Modulon Series
Delta M-3K
Delta M-1K
Delta M-1.5K
Delta M-2K
Delta MBB-RT-1.5K
Delta MBB-RT-2K
Delta MBB-RT-3K
Delta Amplon MBB-RT-20K3P
Delta Amplon MBB-RT15K3P
Delta Categories
Plumbing Product
Kitchen & Bath Fixtures
Bathroom Fixtures
Saw
Power Supply
More Delta Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL