Cisco 300 Series Cli Manual page 98

Small business 300 series managed switches command line interface guide release 1.3
Hide thumbs Also See for 300 Series:
Table of Contents

Advertisement

5
98
current day (if the specified time is later than the current time), or on the next day (if
the specified time is earlier than the current time). Specifying 00:00 schedules the
reload for midnight. The reload must take place within 24 days.
To display information about a scheduled reload, use the
Examples
Example 1—The following example reloads the operating system.
switchxxxxxx#
reload
This command will reset the whole system and disconnect your current session.
Do you want to continue? (y/n) [Y]
Example 2—The following example reloads the operating system in 10 minutes.
switchxxxxxx#
reload in 10
This command will reset the whole system and disconnect your current session.
Reload is scheduled for 11:57:08 UTC Fri Apr 21 2012 (in 10 minutes). Do you
want to continue? (y/n) [Y]
Example 3—The following example reloads the operating system at 13:00.
switchxxxxxx#
reload at 13:00
This command will reset the whole system and disconnect your current session.
Reload is scheduled for 13:00:00 UTC Fri Apr 21 2012 (in 1 hour and 3
minutes). Do you want to continue? (y/n) [Y]
Example 4—The following example shows various usages of this command. Note
that reload in 10 can work without the system clock being set, but reload at
17:12 Jun 6 requires that the system clock be set.
switchxxxxxx# show clock
*16:12:16 UTC Jun 4 2012//please note the '*' on the left side of the time
No time source
switchxxxxxx#reload in 10
System Management Commands
show reload