Cisco 300 Series Cli Manual page 313

Small business 300 series managed switches command line interface guide release 1.3
Hide thumbs Also See for 300 Series:
Table of Contents

Advertisement

Remote Network Monitoring (RMON) Commands
78-21075-01 Command Line Interface Reference Guide
-------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
The following table describes the significant fields shown in the display:
Field
Description
Alarm
Alarm index.
OID
Monitored variable OID.
Last Sample
Value of the statistic during the last sampling
Value
period. For example, if the sample type is delta,
this value is the difference between the samples
at the beginning and end of the period. If the
sample type is absolute, this value is the
sampled value at the end of the period.
Interval
Interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds.
Sample Type
Method of sampling the variable and calculating
the value compared against the thresholds. If the
value is absolute, the variable value is compared
directly with the thresholds at the end of the
sampling interval. If the value is delta, the variable
value at the last sample is subtracted from the
current value, and the difference is compared
with the thresholds.
21
313

Advertisement