• Action list when the trigger type is "Status"
b) When knob 2 selection is "Key Snapshot"
c) When knob 2 selection is "GPI"
6
To confirm the selection, press [Action Set].
This confirms the selection, which appears in the status area.
Test firing the trigger
To test fire the trigger, in the DCU >GPI Output menu press [Test Fire].
This outputs a trigger from the selected output port. This is not output when the
trigger type is "Status."

Serial Port Settings (Serial Port Assign Menu)

To set the protocol to match a device connected to a 9-pin serial port, display
the DCU >Serial Port Assign menu.
To display the Serial Port Assign menu
In the Engineering Setup menu, select VF5 'DCU' and HF5 'Serial Port
Assign.'
The serial port setting status appears in the status area.
When Source Device is SCU: M/E1 Key1 SS ? Recall, M/E1 Key2 SS ? Recall, M/E1
Key3 SS ? Recall
M/E1 Key4 SS ? Recall, M/E2 Key1 SS ? Recall, M/E2 Key2 SS ? Recall, M/E2
Key3 SS ? Recall, M/E2 Key4 SS ? Recall
M/E3 Key1 SS ? Recall, M/E3 Key2 SS ? Recall, M/E3 Key3 SS ? Recall, M/E3
Key4 SS ? Recall
P/P DSK1 SS ? Recall, P/P DSK2 SS ? Recall, P/P DSK3 SS ? Recall, P/P DSK4
SS ? Recall
Editor GPI-?? (executable only when the BZS-8050 license is valid)
No Action
When Source Device is DCU: No Action
When Source Device is SCU: M/E1 Key1 SS ? Recall, M/E1 Key2 SS ? Recall, M/E1
Key3 SS ? Recall, M/E1 Key4 SS ? Recall
M/E2 Key1 SS ? Recall, M/E2 Key2 SS ? Recall, M/E2 Key3 SS ? Recall, M/E2
Key4 SS ? Recall
M/E3 Key1 SS ? Recall, M/E3 Key2 SS ? Recall, M/E3 Key3 SS ? Recall, M/E3
Key4 SS ? Recall
P/P DSK1 SS ? Recall, P/P DSK2 SS ? Recall, P/P DSK3 SS ? Recall, P/P DSK4
SS ? Recall
M/E1 Key1 On, M/E1 Key2 On, M/E1 Key3 On, M/E1 Key4 On
M/E2 Key1 On, M/E2 Key2 On, M/E2 Key3 On, M/E2 Key4 On
M/E3 Key1 On, M/E3 Key2 On, M/E3 Key3 On, M/E3 Key4 On
P/P DSK1 On, P/P DSK2 On, P/P DSK3 On, P/P DSK4 On
Error Make, Error Break, Device Recording, No Action
When Source Device is DCU: Error Make, Error Break, No Action