Knob
Parameter
3
Action
4
Reg No
a) • Action list when the trigger type is other than "Level"
When Target is M/E-1, M/E-2, or M/E-3: Cut, Auto Trans
Key1 Cut, Key1 Auto Trans, Key2 Cut, Key2 Auto Trans, Key3 Cut, Key3 Auto
Trans, Key4 Cut, Key4 Auto Trans
SS ? Recall, Key1 SS ? Recall, Key2 SS ? Recall, Key3 SS ? Recall, Key4 SS ?
Recall
Effect ? Recall, Effect ? Recall & Run, KF Run, KF Stop, KF Rewind, KF Reverse
Run, No Action
When Target is P/P: Cut, Auto Trans
DSK1 Cut, DSK1 Auto Trans, DSK2 Cut, DSK2 Auto Trans, DSK3 Cut, DSK3
Auto Trans, DSK4 Cut, DSK4 Auto Trans
FTB Cut, FTB Auto Trans
SS ? Recall, DSK1 SS ? Recall, DSK2 SS ? Recall, DSK3 SS ? Recall, DSK4 SS
? Recall
Effect ? Recall, Effect ? Recall & Run, KF Run, KF Stop, KF Rewind, KF Reverse
Run, No Action
When Target is Common/Setup: FM Src1 Field Freeze, FM Src1 Frame Freeze, FM
Src2 Field Freeze, FM Src2 Frame Freeze
FM Src1 Freeze Off, FM Src2 Freeze Off
FM Src1 Clip Record, FM Src1 Clip Stop, FM Src2 Clip Record, FM Src2 Clip
Stop, FM1 to FM8 Clip Cueup, FM1 to FM8 Clip Play, FM1 to FM8 Clip Stop,
User1 to 8 SS ? Recall, User1 to 8 EFF ? Recall, User1 to 8 EFF ? Recall & Run,
User1 to 8 KF Run, User1 to 8 KF Stop, User1 to 8 KF Rewind, User1 to 8 KF
Reverse Run, No Action
(FM Src1(2) Clip Record/Stop, and FM1 to FM8 Clip Cueup/Play/Stop do not
operate on the MVS-8000.)
• Action list when the trigger type is "Level"
When Target is M/E-1, M/E-2, M/E-3, or P/P: Aspect
Bkgd A Side Flags*, Bkgd B Side Flags*
* Appears on the MVS-8000A/8000G only.
No Action
When Target is Common/Setup: Format, Aspect, Level Enable, No Action
Notes
• "Level Enable" is a function that determines whether GPI inputs are enabled
("Enable") or disabled ("Disable") for the "Aspect" and "Format" actions that can
be used when the trigger type is Level. When Level Enable is used, if the input is
"Disable" then it is not possible to switch "Aspect" or "Format" by GPI input.
If a GPI to switch "Aspect" or "Format" occurs when powering the system off, the
action triggered by the GPI may start immediately before the power goes off and
the power may go off before the action is completed. This may corrupt the setup
settings. It is therefore recommended to use Level Enable to avoid such a situation.
• If "Format" is selected for "Action" when the format converter is used on the MVS-
8000G, you can set the conversion formats of the format converter for "FC Input 1-
8" and "FC Input 9-16".
b) When knob 3 selection is "Key Snapshot"
c) When knob 3 selection is "Snapshot" or "Effect"
6
Press [Action Set] to confirm the action selection.
Adjustment
Action selection
Register number
Setup Relating to Switcher Processor
Setting values
a)
1 and upwards
b)
1 to 4
c)
1 to 99