3
Assigning two M/E banks to one M/E bank
1
2
To return to the original assignment
Interchange the bank order (see page 321).
Interchanging shifted and non-shifted operations for a dual M/E
1
322
Setup Relating to Operations From the Control Panel
For the selected Bank number, in the <M/E Operation> group, select one
of the following.
Enable: Enable panel display and operation of the bank.
Disable: Enable only panel display, and disable operation of the bank.
Inhibit: Disable both the panel display and operation of the bank.
Note
When this is set to Inhibit, snapshots of the bank are not recalled.
In the Panel >Config menu, select the M/E bank for which you want to
make the setting.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob
Parameter Adjustment
1
Bank
Selection of position of bank for which you
want to make the setting
a) Depends on the center control panel configuration. When the bank closest to the operator
(the 4th row of a 4-M/E system) is selected, [Dual M/E Assign] is disabled.
For example, if the furthest bank from you is assigned to M/E-1, and you
want no shift button operation for the bank, select 1 (1st Row) for Bank.
Press [Dual M/E Assign].
This assigns the furthest M/E bank from you to the unshifted (shifted)
cross-points and the M/E bank in front of it to the shifted (unshifted) cross-
points. For fader lever operations, only the M/E bank closer to you is
enabled.
The shift/non-shift assignment is set by [Dual M/E Xpt Swap]. For more
details, see the next section, "Interchanging shifted and non-shifted
operations for a dual M/E."
In the Panel >Config menu, select the M/E bank for which the dual M/E
setting is made.
Setting values
a)
1 to 4