Sony MVS-8000 User Manual page 413

With ccp-8000 series center control panel
Hide thumbs Also See for MVS-8000:
Table of Contents

Advertisement

7
8
To delete a link
Select the link you want to delete, then press [Clear] in the Switcher >Link
>Internal Bus Link menu.
Making link table settings
1
2
3
To initialize the set source address
In the Switcher >Link >Link Table Select menu, press [Init Link Table].
A confirmation message appears; press [Yes].
The source addresses are reassigned, and this is reflected in the status area.
To change the link number and link table number
In this menu too, you can change the link number and link table number. To do
this, turn the knobs as follows to make the setting, then press [Link Table Set].
412
Setup Relating to Switcher Processor
Referring to step 5, select the bus to be the link destination, and press [Bus
Set].
Turn the knob to select the link table, and press [Link Table Set].
Knob Parameter
3
Link Table No
For more information about link tables, see the following item.
The status area reflects the current setting status.
In the Switcher >Link >Internal Bus Link menu, press [Link Table Select].
The Link Table Select menu appears.
Using any of the following methods, select the link source and link
destination signals.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
Knob
Parameter
Adjustment
4
Main No
Video/key signal for link source
5
No
Video/key signal for link destination
To confirm the selection, press [Link Src Set].
This links the link destination signal to the signal selected as Main No.
Adjustment
Link table selection
Setting values
1 to 8
Setting values
1 to 128
1 to 128