Sony MVS-8000 User Manual page 445

With ccp-8000 series center control panel
Hide thumbs Also See for MVS-8000:
Table of Contents

Advertisement

3
4
5
6
7
8
444
Setup Relating to DCU
Knob
Parameter
Adjustment
1
Port No
Serial port number
a) The range of setting values depends on the DCU port setting. (When the MKS-2700 is
connected, select 2 for the slot and a value in the range 1 to 6 for the port.)
Press [Port Setting].
The DCU >Serial Port Assign >P-Bus Setting menu appears.
At the top of the status area, the relevant serial port, slot number, protocol,
serial port name, and SCU number appear. In the lower part of the status
area, the device name and response speed settings appear.
Using any of the following methods, select the ID for which you want to
make a device name setting.
• Press directly on the device name list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob
Parameter
Adjustment
1
ID
ID selection
In the <Name> group, press [Set] to display a numeric keypad window.
Input the desired name, and press [Enter].
The input device name appears in the device name list.
To return the device name for the selected ID to the default name
In the <Name> group, press [Clear].
Using any of the following methods, specify the command to which the
response speed setting applies.
• Press directly on the delay list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob
Parameter
Adjustment
2
No
Command number selection
Turn the knob to set the response speed (in field units) of the device.
Knob
Parameter
Adjustment
3
Delay
Response speed setting
Setting values
a)
1 and upwards
Setting values
0 to 23
Setting values
1 to 18
Setting values
0 to 60

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvs-8000sf

Table of Contents