Sony MVS-8000 User Manual page 428

With ccp-8000 series center control panel
Hide thumbs Also See for MVS-8000:
Table of Contents

Advertisement

Press [Unity] in the <Crop> group.
Setting an illegal color limit for matte signals
To enable the illegal color limiter for the signals generated by the DME internal
matte generator, press [Matte Illeg Col Limit] for DME1 in the DME >Input
menu, turning it on.
Making DME system phase adjustment
To adjust the DME reference phase, use the following procedure.
1
In the DME >Input menu, press [System Phase].
2
Set the following parameters.
Knob
1
2
Setting the TBC window center position
When the MVE-8000A/MVE-9000 is connected through SDI interface, the
DME >Input >TBC Center menu allows you to set the TBC window center
position.
1
In the DME >Input menu, press [TBC Center].
The TBC Center menu appears.
The status area shows the TBC center position values for DME1, DME 2,
and external input signals.
Note
The TBC center position values for external input signals are shown only
when an SDI-interfaced MVE-9000 is used.
2
Using any of the following methods, select the input number for which you
want to set the TBC center position.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Parameter
Adjustment
DME1
DME1 system phase adjustment
Phase
DME2
DME2 system phase adjustment
Phase
Setting values
–32.00 to +96.00
–32.00 to +96.00
427
Setup Relating to DME

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvs-8000sf

Table of Contents