Reset and Initialization (Initialize Menu)

To carry out a reset or memory initialization for a device, use the System
>Initialize menu.
To display the Initialize menu
In the Engineering Setup menu, select VF1 'System' and HF5 'Initialize.'
The status area shows the current start-up mode settings.
Resetting the device and initializing memory
1
In the status area of the System >Initialize menu, select the device to which
the settings are to apply.
2
In the <Initialize> group, select one of the following modes.
Reset: Reset the device.
All Clear: Initialize memory.
3
Press [Execute].
A confirmation message appears.
4
Select [Yes].
Depending on the selection in step 2, the following is the result.
• When you selected [Reset], a reset is applied to the device causing it to
be restarted in the start-up state.
• When you selected [All Clear], all memory in the device is cleared,
including snapshots, keyframe effects, setup, and so on, and the device
returns to its factory default settings. However, the Network Config,
Format, Start Up, and Date/Time settings are not initialized.

Installation and Device Setup (Install/Unit Config Menu)

To install software or firmware in a device, use the System >Install/Unit
Config menu.
To display the Install/Unit Config menu
In the Engineering Setup menu, select VF1 'System' and HF6 'Install/Unit
Config.'
The status area shows the version of the software and the firm ware installed in
each device.