2.20
2-32
Emerald ICE Installation & Hardware Reference Manual
Power Consumption Table
Condition
Required AC power
Power consumption per
EKT phone set
Power consumption per
SLT phone set
Power consumption of
board
Power consumption of
Voice mail card (Flash
version)
Power consumption of
Voice mail card (HD
version)
Example:
Full Load system configuration with 22 EKT phone sets and 8 SLT phone sets the
power consumption at the AC line is 15(KSU1)+3.2(4SLTx2, 6CO, 12EKT) +
4(EKTx22)+12(SLTx8) = 74.2W (max).
Cabinet(s)
Max (Watts)
KSU 1
150
(610+2/B &
CCB)
KSU 2
150
(BASE/B
Only)
KSU 1 & 2
+2 @ Hands‐free
KSU 1 & 2
+1.5 @ Off‐hook
+0.9 @ Ringing
KSU 1
+1.5 (610+2/B)
+3 (CC/B)
KSU 1 & 2
+0.8
(4SLT/B, 6CO/B
12EKT)
KSU 1
+2
KSU 1
+6
Min (Watts)
10
5
+1.5 @ Idle
0 @ On‐hook
‐
‐
‐
‐
‐