RMP Programming
1. Access the RMP using the procedures described in Section 3.3.
2. Select RP, System Application, Time Switching from the toolbar to display
the following window.
3. Enter the time when this service mode should become active in the Start
column and when it should stop being active in the End column‐for each
Tenant Group. The times should be entered in 24‐hour format. The settings
of the service switching are based on the days of a week. That is, on each
day of a week, each tenant can has its particular time table for switching its
day‐night services. If the Tenant 1 check box has been checked, the
associated tenant will take the time table of Tenant 1 to switch its service
mode and ignore its own switching times.
4. Click on the Close button to close the window without making changes or
click on the Update button and follow the prompts to save the database
changes.