docsis cvc mfg
docsis cvc mfg
To configure the access start times and organization name for the manufacturer's code verification
certificate (CVC) to enable the DOCSIS 1.1 secure software download feature on the router, use the
docsis cvc mfg command in global configuration mode. To delete this information, use the no form of
this command.
Cisco uBR905 and Cisco uBR925 cable access routers, and Cisco CVA122 Cable Voice Adapter
Syntax Description
codeAccessStart
start-time
cvcAccessStart
start-time
organization name
Defaults
The codeAccessStart and cvcAccessStart times default to 011219000000Z (midnight on December 19,
2001 Greenwich Mean Time). The organization defaults to Cisco Systems.
Typically, the default values should not be changed unless you are instructed to do so by Cisco TAC or
Note
field service engineers.
Command Modes
Global configuration
Command History
Release
12.2(15)CZ
Usage Guidelines
This command configures the access start times and organization name that are required by Appendix D
in the DOCSIS BPI+ specification. The time values are specified as UTC time values in Greenwich Mean
Time, with a two-digit year. If the year is between 50 and 99, it is interpreted as 1950 to 1999. If the year
is between 00 and 49, it is interpreted as 2000 to 2049.
The router uses the codeAccessStart value to verify the Code Verification Signature (CVS) that is
affixed to the code file downloaded using the secure software download feature. The router uses the
ccvAccessStart value to verify the CVC for the code file. The router also uses the organization value
to verify that the code file has been created by the proper manufacturer.
Cisco Broadband Cable Command Reference Guide
6-38
docsis cvc mfg {codeAccessStart start-time | cvcAccessStart start-time | organization name}
no docsis cvc mfg {codeAccessStart start-time | cvcAccessStart start-time | organization name}
Specifies the code Access Start Time as a UTC time value
(YYMMDDhhmmssZ) in Greenwich Mean Time.
Specifies the CVC Access Start Time as a UTC time value
(YYMMDDhhmmssZ) in Greenwich Mean Time.
Specifies the name of the manufacturer of the code file. Use quotes if the
name value contains more than one word.
Modification
This command was introduced on the Cisco uBR905 and Cisco uBR925
cable access routers, and the Cisco CVA122 Cable Voice Adapter.
Chapter 6
Cable CPE Commands
OL-1581-07

Advertisement

Table of Contents
loading

This manual is also suitable for:

Broadband cable

Table of Contents