Smart Link Device Configuration Example

Network requirements
Create smart link group 1.
The protected VLANs of smart link group 1 are mapped to MSTI 0 through 8.
Configure GigabitEthernet 2/0/1 as the master port of the smart link group, and GigabitEthernet
2/0/2 as the slave port.
Configure VLAN 20 for flush update.
Configure the collaboration between Smart Link and the CC function of CFD on GigabitEthernet
2/0/1 and GIgabitEthernet 2/0/2.
Configuration procedure
<Sysname> system-view
[Sysname] vlan 20
[Sysname-vlan20] quit
[Sysname] interface gigabitethernet 2/0/1
[Sysname-GigabitEthernet2/0/1] undo stp enable
[Sysname-GigabitEthernet2/0/1] port link-type trunk
[Sysname-GigabitEthernet2/0/1] port trunk permit vlan 20
[Sysname-GigabitEthernet2/0/1] quit
[Sysname] interface gigabitethernet 2/0/2
[Sysname-GigabitEthernet2/0/2] undo stp enable
[Sysname-GigabitEthernet2/0/2] port link-type trunk
[Sysname-GigabitEthernet2/0/2] port trunk permit vlan 20
[Sysname-GigabitEthernet2/0/2] quit
[Sysname] smart-link group 1
[Sysname-smlk-group1] protected-vlan reference-instance 0 to 8
[Sysname-smlk-group1] port gigabitethernet 2/0/1 master
[Sysname-smlk-group1] port gigabitethernet 2/0/2 slave
[Sysname-smlk-group1] flush enable control-vlan 20
[Sysname-smlk-group1] quit
[Sysname] interface gigabitethernet 2/0/1
[Sysname-GigabitEthernet2/0/1] port smart-link group 1 track cfd cc
[Sysname-GigabitEthernet2/0/1] quit
[Sysname] interface gigabitethernet 2/0/2
[Sysname-GigabitEthernet2/0/2] port smart-link group 1 track cfd cc

Configuring an Associated Device

Enabling the Receiving of Flush Messages

You do not need to enable all ports on the associated devices to receive flush messages sent from the
transmit control VLAN, only those on the master and slave links between the smart link device and the
destination device.
Follow these steps to enable the receiving of flush messages:
1-9

Hide quick links:

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S7906E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

S7910eS7906e-vS7903eS7903e-sS7902e

Table of Contents