Configuring The Poe Monitoring Function; Configuring Poe Power Supply Monitoring - 3Com S7906E Configuration Manual

S7900e family release 6600 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

To do...
Configure the power supply
priority for a PoE interface

Configuring the PoE Monitoring Function

After the PoE monitoring function is enabled, the system monitors the parameter values related to PoE
power supply, PSE, PD, and device temperature in real time. When a specific value exceeds the
limited range, the system will automatically take some measures to protect itself.

Configuring PoE Power Supply Monitoring

PoE power supply converts AC power to specific DC power and supplies to PSEs. Exceptions of AC
input voltage and DC output voltage of PoE power supply directly affect the PSEs to supply power to
PDs. You can configure monitoring over AC input voltage and DC output voltage of PoE power supply.
When a specific monitored item reaches the threshold, the system will generate trap message to notify
the administrator of the PoE power supply exception.
Follow these steps to configure PoE power supply monitoring:
To do...
Enter system view
Configure an AC input
under-voltage threshold for the
PoE power supply
Configure an AC input
under-voltage threshold for the
PoE power supply (distributed
IRF device)
Configure an AC input
over-voltage threshold for the
PoE power supply
Configure an AC input
over-voltage threshold for the
PoE power supply (distributed
IRF device)
Configure a DC output
under-voltage threshold for the
PoE power supply
Configure a DC output
under-voltage threshold for the
PoE power supply (distributed
IRF device)
Configure a DC output
over-voltage threshold for the
PoE power supply
Use the command...
poe priority { critical | high | low }
Use the command...
system-view
poe-power input-threshold
lower value
poe-power input-threshold
chassis chassis-number lower
value
poe-power input-threshold
upper value
poe-power input-threshold
upper value
poe-power output-threshold
lower value
poe-power output-threshold
chassis chassis-number lower
value
poe-power output-threshold
upper value
1-10
Remarks
Optional
low by default.
Remarks
Optional
The default AC input
under-voltage threshold is
90.00.
Optional
The default AC input
under-voltage threshold is
90.00.
Optional
The default AC input
over-voltage threshold is
264.00.
Optional
The default AC input
over-voltage threshold is
264.00.
Optional
The default DC output
under-voltage threshold is
47.00.
The default DC output
under-voltage threshold is
47.00.
Optional
The default DC output
over-voltage threshold is 55.00.