Troubleshooting Ead Fast Deployment; Users Cannot Be Redirected Correctly - 3Com S7906E Configuration Manual

S7900e family release 6600 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

Reply from 192.168.2.3: bytes=32 time<1ms TTL=128
Reply from 192.168.2.3: bytes=32 time<1ms TTL=128
Ping statistics for 192.168.2.3:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 0ms, Maximum = 0ms, Average = 0ms
Besides, if the user uses IE to access any external website, the user will be taken to the WEB server,
which provides the client software download service.

Troubleshooting EAD Fast Deployment

Users Cannot be Redirected Correctly

Symptom
When a user enters an external website address in the IE browser, the user is not redirected to the
specified URL.
Analysis
The address is in the string format. In this case, the operating system of the host regards the string
a website name and tries to have it resolved. If the resolution fails, the operating system sends an
ARP request with the address in the format other than X.X.X.X. The redirection function does
redirect this kind of ARP request.
The address is within the freely accessible network segment. In this case, the device regards that
the user is trying to access a host in the freely accessible network segment, and redirection will not
take place, even if no host is present with the address.
The redirect URL is not in the freely accessible network segment, no server is present with that
URL, or the server with the URL does not provide WEB services.
Solution
Enter an IP address that is not within the freely accessible network segment in dotted decimal
notation (X.X.X.X).
Ensure that the device and the server are configured correctly.