Configuring the Clock Synchronization Timer
Follow these steps to configure the clock synchronization timer:
To do...
Enter system view
Enable the ACSEI server
function
Enter ACSEI server view
Configure the clock
synchronization timer from
ACSEI server to ACSEI client
Configuring the Monitoring Timer
Follow theses steps to configure the monitoring timer:
To do...
Enter system view
Enable the ACSEI server
function
Enter ACSEI server view
Configure the monitoring timer
for ACSEI server to monitor
ACSEI client
Closing an ACSEI Client
Follow these steps to close an ACSEI client:
To do...
Enter system view
Enable the ACSEI server
function
Enter ACSEI server view
Close the specified ACSEI
client
Restarting an ACSEI Client
Follow these steps to restart an ACSEI client:
To do...
Enter system view
Enable the ACSEI server
function
Use the command...
system-view
acsei server enable
acsei server
acsei timer clock-sync
minutes
Use the command...
system-view
acsei server enable
acsei server
acsei timer monitor seconds
Use the command...
system-view
acsei server enable
acsei server
acsei client close client-id
Use the command...
system-view
acsei server enable
1-3
Remarks
—
Required
—
Optional
Five minutes by default.
Remarks
—
Required
—
Optional
Five seconds by default.
Remarks
—
Required
—
Required
Remarks
—
Required
Need help?