[SwitchA-Tunnel1] tunnel-protocol mpls te
[SwitchA-Tunnel1] destination 4.4.4.9
[SwitchA-Tunnel1] mpls te tunnel-id 10
[SwitchA-Tunnel1] mpls te signal-protocol rsvp-te
[SwitchA-Tunnel1] mpls te bandwidth 2000
[SwitchA-Tunnel1] mpls te commit
[SwitchA-Tunnel1] quit
6)
Verify the configuration
Perform the display interface tunnel command on Switch A. You can find that the tunnel interface is
up.
[SwitchA] display interface tunnel
Tunnel1 current state: UP
Line protocol current state: UP
Description: Tunnel1 Interface
The Maximum Transmit Unit is 64000
Internet Address is 7.1.1.1/24 Primary
Encapsulation is TUNNEL, service-loopback-group ID not set
Tunnel source unknown, destination 4.4.4.9
Tunnel protocol/transport CR_LSP
Last 300 seconds input:
Last 300 seconds output:
0 packets input,
0 input error
0 packets output,
0 output error
Perform the display mpls te tunnel-interface command on Switch A to verify information about the
MPLS TE tunnel.
[SwitchA] display mpls te tunnel-interface
Tunnel Name
Tunnel Desc
Tunnel State Desc :
Tunnel Attributes :
LSP ID
Session ID
Admin State
Ingress LSR ID
Signaling Prot
Class Type
Reserved BW
Setup Priority
Affinity Prop/Mask
Explicit Path Name
Tie-Breaking Policy :
Metric Type
Record Route
FRR Flag
0 bytes/sec, 0 packets/sec
0 bytes/sec, 0 packets/sec
0 bytes
0 bytes
:
Tunnel1
:
Tunnel1 Interface
CR-LSP is Up
:
1.1.1.9:3
:
10
:
UP
:
1.1.1.9
:
RSVP
:
CLASS 0
:
0 kbps
:
7
:
0x0/0x0
:
-
None
:
None
:
Disabled
Record Label :
:
Disabled
BackUpBW Flag:
1-49
Oper State
:
UP
Egress LSR ID:
4.4.4.9
Resv Style
:
SE
Tunnel BW
:
0 kbps
Hold Priority:
7
Disabled
Not Supported